Model of Outdoor Unit
Compressor Model
Compressor Type
L.R.A. (A)
Compressor RLA(A)
Compressor Power Input(W)
Overload Protector
Throttling Method
Starting Method
Working Temp Range ( ℃ )
Condenser
Pipe Diameter (mm)
Rows-Fin Gap(mm)
Coil length (l) x height (H) x coil width (L)
Fan Motor Speed (rpm) (H/M/L)
Output of Fan Motor (W)
Fan Motor RLA(A)
Outdoor
Fan Motor Capacitor (uF)
unit
Air Flow Volume of Outdoor Unit
Fan Type-Piece
Fan Diameter (mm)
Defrosting Method
Climate Type
Isolation
Moisture Protection
Permissible Excessive Operating
Pressure for the Discharge Side(MPa)
Permissible Excessive Operating
Pressure for the Suction Side(MPa)
Sound Pressure Level dB (A) (H/M/L)
Sound Power Level dB (A) (H/M/L)
Dimension (W/D/H)( mm)
Dimension of Package (W/D/H)( mm)
Net Weight /Gross Weight (kg)
Refrigerant Charge (kg)
Length (m)
Connec
Outer Diameter
tion
Pipe
Max Distance
The above data are subject to change without notice. Please refer to the nameplate of the unit.
Liquid Pipe (mm)
Gas Pipe (mm)
Height (m)
Length (m)
KFR-80W/A22-C
ZR36KH-PFJ-522
Hermetic motor compressor
100
17.1
2730
Internal Inherent Protector
Capillary
Capacitor
-5 ≤ T ≤ 43
Aluminum fin-copper tube
Φ 9.52
2-1.4
1017.5X813X44
920
92
2.26
3.5
----
Axial fan –1
Φ 482
Auto defrost
T1
I
IP24
2.5
0.6
60
70
950X412X840
1100X450X995
90/100
R22 / 2.75kg
5
Φ 9.52(3/8")
Φ 16(5/8")
15
30