General Characteristics - CAME C Series Standard Installation

Automation systems for industrial applications
Hide thumbs Also See for C Series:
Table of Contents

Advertisement

ENGLISH
Description of control panel
The ZC3 electric panel is suitable for
controlling the automation of series
C and F3000, 230V sliding industrial
gates, with up to 600W power and 50-
60 Hz frequency.
Wholly designed and built by CAME
S.p.A., it meets UNI 8612 regulations
in force. ABS Case with an IP54 pro-
tective level, with air recycling inlet and
transformer.
The circuit requires 230V (a.c.) at
terminal blocks L1- L2 and the inlet is
protected with two 5A fuses, whilst the
low voltage command devices are pro-
tected by a 1A fuse.
The accessories' total wattage (24V)
must not exceed 20W.
The panel includes a manoeuvre pick-
up function. This function is activated
during the initial phase of the gate's
opening and closing.
Safety
Photocells can be connected to obtain:
- Re-opening during closure (2-C1), if
the photocells identify an obstacle whi-
le the gate is closing, they will reverse
the direction of movement until the
gate is completely open;
- Re-closing during opening (2-CX, see
dip n°8 to OFF - 9 to OFF), if the pho-
tocells identify an obstacle while the
gate is opening, they will reverse the
-4-

GENERAL CHARACTERISTICS

direction of movement until the gate is
completely close;
- Partial stop, shutdown of moving
gate, with activation of an automatic
closing cycle (2-CX, dip n°8 OFF - 9
ON);
- Total stop (1-2), shutdown of gate
movement without automatic closing;
a pushbutton or radio remote control
must be actuated to resume move-
ment.
N.B: If an NC safety contact (2-C1,
2-CX, 1-2) is opened, the LED (pag.12
-n°8) will flash to indicate this fact;
- Obstacle presence detection. When
the motor is stopped (gate is closed,
open or half-open after an emergency
stop command), the transmitter and
the control pushbutton will be deacti-
vated if an obstacle is detected by one
of the safety devices (for example, the
photocells);
- Safety test function. The control unit
will now check the safety system every
time an opening or closing command is
given (see p.18).
Accessories which can be con-
nected to this unit
- Cycle lamp. The lamp which lights the
manoeuvring zone: it remains lit from
the moment the doors begin to open
until they are completely closed (inclu-
ding the time required for the automatic

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C 100C byC byt

Table of Contents