SONAS_results.txt file, and open it. Check for errors and corrective actions.
Refer to Storwize V7000 Unified Problem Determination Guide PDF on the CD.
v If no errors are listed, reboot the server (allow server to start), reinsert the USB
flash drive, and try again.
Blue LED on the other file module (without USB flash drive) keeps flashing
(does not turn solid or off as listed in instructions):
Wait for the primary file module to start flashing, remove the USB flash drive,
insert it into you laptop, verify the InitTool set up information is correct , navigate
to the SONAS_results.txt file and open it. Check for errors and corrective actions
(refer to Storwize V7000 Unified Problem Determination Guide PDF on the CD). If no
errors are listed, reboot both file modules, allow file modules to boot completely,
reinsert the USB flash drive as originally instructed and try again.
Installed with the incorrect control enclosure or file module IP addresses:
If it is determined that the addresses were entered incorrectly, they can be changed
at the command line as user admin with the following commands:
v For control enclosure IP changes use: svctask chsystemip
v For file module management node changes use: chnwmgt
Refer to the man pages for usage.
The file module initialization may have failed because of a duplicate IP
address:
The control enclosure may have been set up with an IP address which is already in
use by another machine on your network but the initial setup of the file modules
has failed. Refer to Checking that IP addresses are not already in use from the
Information Center, under the Installing topic.
Chapter 7. Problems with initial setup