and data (if needed). All 10 Gbps Ethernet ports are dedicated to data.
Management cannot be performed over the 10 Gbps Ethernet.
Note: It is important that the file modules are able to communicate over the
network with the Storwize V7000 control enclosure for management, service and
optional file access.
Figure 50. Control enclosure Ethernet network connections.
v
v
v
v
Figure 51. Storwize V7000 Gen2 control enclosure Ethernet network connections
90
IBM Storwize V7000 Unified: Adding Storwize V7000 File Modules to an existing Storwize V7000 system 2073-720
2
1
CAUTIO N
Disconnect all
supply power for
complete isolation
1 Fibre Channel ports (8 Gbps). Each canister has four Fibre Channel ports.
They are in a block of four in two rows of two connectors. The ports are
numbered 1 - 4 from left to right, top to bottom. Two ports connect to the file
modules and two are connected to the SAN.
2 USB ports. Each canister has two USB ports. The ports are side by side on
the canister and are numbered 1 on the left and 2 on the right. One port is used
during installation.
3 Ethernet ports (1 Gbps). Each canister has two Ethernet ports. The ports are
side by side on the canister. They are numbered 1 on the left and 2 on the right
on the upper canister. The port locations are inverted for the lower canister. Port
1 must be connected first; the use of port 2 is optional.
4 Serial-attached SCSI (SAS) ports (6 Gbps). Each canister has two SAS ports.
The ports are side by side on the canister. They are numbered 1 on the left and 2
on the right. Port 1 must be connected first if you are adding one expansion
enclosure. Port 2 must be connected if you are adding a second expansion
enclosure.