IBM Storwize V7000 Unified Manual page 102

Adding storwize v7000 file modules
Table of Contents

Advertisement

v Do not extend more than one device out of the rack cabinet at the same time.
v Remove the rack doors and side panels to provide easier access during
v Do not overload the power outlet when you install multiple devices in the rack
v Install the file module in a rack that meets the following requirements:
v Install the cable management arm on either side of the file module. These
Figure 35 shows the items that you need to install the file module in the rack
cabinet. If any items are missing or damaged, contact your place of purchase. The
contents from the slide rail box and the cable management arm box are necessary
for this installation.
Figure 35. Cable management arm box contents
Figure 36 on page 83 shows the friction rail box contents.
82
IBM Storwize V7000 Unified: Adding Storwize V7000 File Modules to an existing Storwize V7000 system 2073-720
installation.
cabinet.
– Minimum depth of 70 mm (2.76 inch) between the front mounting flange and
inside of the front door.
– Minimum depth of 157 mm (6.18 inch) between the rear mounting flange and
inside of the rear door.
– Minimum depth of 718 mm (28.27 inch) and maximum depth of 762 mm (30
inch) between the front and rear mounting flanges to support the use of the
cable management arm.
Note: The maximum distance between the front and the rear EIA rails of the
rack is 810 mm (31.9 inch). Also, cage nuts and clip nuts are not required to
install the file module in a rack cabinet.
instructions are shown with the cable management arm mounted on the left
side. The installation instructions in this document can be reversed if you are
installing the cable management arm on the side of the file module not shown.
1
1 Cable-management support bar
2 Cable-management arm assembly
3 Cable-management stop bracket
2
3