Fujitsu Halcyon Operating Manual page 7

Wall mounted type
Hide thumbs Also See for Halcyon:
Table of Contents

Advertisement

Available languages

Available languages

Timer Operation
SLEEP timer
To set the SLEEP timer, rst follow steps 1~3 for the ON/OFF timer.
4.
Adjust the time by pressing the SELECT button while the clock
indicator is blinking.
Each time you press the button, the time changes as follows:
0H
1H
2H
30M
00M
00M
(30 min.)
5.
Press the SEND button.
To cancel the SLEEP timer, press the SLEEP button while the SLEEP
indicator is on. (Erases the indicator)
To help you to fall asleep comfortably and prevent excessive warming
or cooling in sleep, the SLEEP timer controls the temperature setting
automatically in accordance with the set time shown as follows. The
air conditioner completely turns off after the set time has elapsed.
In HEAT mode
2 °F (1 °C) 4°F (2 °C) 6°F (3 °C) 8°F (4 °C)
30 min.
1 hour
1.5 hour
Set time
WEEKLY timer
ON and OFF timer can be combined, and up to 4 reservations (program
) per day and 28 reservations per week.
Before setting the program, please set the week and time of the air
conditioner rst.
If the week and time are not set, the weekly timer will not operate
correctly at the set time.
Please refer to "remote controller preparation" (page 3).
Example of WEEKLY timer 1
Program
Program
Monday to
7:00 ON 76°F (24.0 °C)
9:00 OFF
Friday
Wake up
Leave for work
Saturday
Program
Program
Sunday
ON
ON
9:00 OFF
11:00 OFF
Example of WEEKLY timer 2
You can specify a given temperature in the ON setting in WEEKLY
timer.
Program
Program
7:00 ON 72°F (22.0 °C)
9:00 ON 76°F (24.0 °C)
* You can set the temperature for AUTO, COOL, and DRY modes within
the range of 64-88°F (18.0-30.0 °C), for Heat mode the range is 50 or
60-88°F (10.0 or 16.0-30.0 °C).
Even if you set to 50, 60 or 62°F (10.0, 16.0 or 17.0 °C), if you run the
product on AUTO, COOL, or DRY, it will run at 64°F (18.0 °C).
Notes:
Operations modes other than the temperature setting will be the
same at the last time operation was stopped, so Cooling
Cooling
Heating type of operations cannot be automatically
set.
If you set the ON timer and OFF timer on the same time, the air
conditioner will run the ON timer. If two ON timer are set at the
same time, the air conditioner will run in the order of the program
number.
3H
5H
7H
9H
00M
00M
00M
00M
hours
In COOL or DRY mode
Set time
Set
temperature
1 hour
2 °F (1 °C)
Program
Program
17:00 ON 80°F (26.0 °C)
23:00 OFF
Come back home
Go to sleep
No timer settings
Program
Program
ON
ON
23:00 OFF
17:00 OFF
Program
Program
17:00 ON 80°F (26.0 °C)
23:00 ON 72°F (22.0 °C)
Heating
If there is a power interruption, such as due to a power outage
during the WEEKLY timer setting or a circuit breaker cutting out,
the internal timer of the air-conditioning will be incorrect. (See page
8 "Auto-restart function".) In such a case, the main timer lamp will
notify you of this by ashing, so carry out matching of the time and
date. (See page 3 "remote controller preparation".)
You cannot use the WEEKLY timer together with the other timers.
If you want to run the product on WEEKLY timer after using the ON/
OFF Timer, Program Timer, or SLEEP Timer while the WEEKLY
timer is running, you need to activate the WEEKLY timer again.
To set the WEEKLY timer, rst follow steps 1~3 for the ON/OFF timer.
4.
Select the program number and the day using the SELECT button.
Program
1Week
1Week Program
Program
4°F (2 °C)
Press the NEXT button, when the program number and day you
want to set are ashing.
5.
Using the SELECT button select the operation mode (ON timer,
OFF timer, or without a timer).
To operate without a timer
1. Press the NEXT button to go back to step 4 and con gure the
next setting.
2. Press the SEND button to nish
Press the NEXT button.
6.
Press the SELECT button to set the desired ON time or OFF time.
If you selected OFF in step 5
1. Press the NEXT button to go back to step 4 and con gure the
next setting.
2. Press the SEND button.
Press the NEXT button.
7.
Press the SELECT button to set the temperature.
If you want to move on to the next setting, press the NEXT button,
return to step 4 and con gure the next setting.
8.
To complete the setting, press the SEND button.
If you want to cancel the setting midway, please press the
TIMER SETTING button instead of pressing the SEND button.
Notes:
When canceling the WEEKLY timer, select No Timer Operation in
Step 5 in the WEEKLY timer setting.
If you want to go back to the previous step when con guring
settings, press the BACK button to return to the previous step.
Press the SEND button, when you are close to the main unit. If you
do so when far from the main unit, the signal may not get properly
sent, and the settings may not get properly con gured.
To check the schedule, repeat steps 1 to 3 to enter the WEEKLY
timer mode, then use the SELECT button to browse through the
WEEKLY timer settings in the order shown in step 4.
To cancel the WEEKLY timer, press the WEEKLY button while the
WEEKLY indicator is on. (Erases the indicator)
When operating from central control , please do not use the Weekly timer.
Do not use the weekly timer when using external devices for
Centralized control.
AIR CONDITIONER Wall Mounted Type
Monday Program
Tuesday
Program
Monday
Program
Saturday Program
OPERATING MANUAL
Program
Sunday
Sunday
En-7

Advertisement

Table of Contents
loading

Table of Contents