Summary of Contents for Fujitsu Halcyon ASU9RQ

  • Page 1 ASU9RQ ASU12RQ AOU9RQ AOU12RQ...
  • Page 2 Fig. 1 Indoor Unit Fig. 6 Remote Control Unit H MASTER CONTROL button 1 Operating Control Panel (Fig. 2) I SET TEMP. / SET TIME buttons (+/-) 2 AIR CLEANER RESET / MANUAL AUTO J Signal Transmitter button K TIMER button Intake grill opening mechanism.
  • Page 3: Features And Functions

    FEATURES AND FUNCTIONS AUTO CHANGEOVER MILDEW-RESISTANT FILTER The operation mode (cooling, heating) is switched The AIR FILTER has been treated to resist mildew growth, automatically to maintain the set temperature, and the thus allowing cleaner use and easier care. temperature is kept constant at all times. SUPER QUIET OPERATION SLEEP TIMER When the FAN CONTROL button is used to select QUIET,...
  • Page 4 PREPARATION CAUTION! Turn on the Power G Take care to prevent infants from accidentally swallowing batteries. In the case of a direct line connection, turn on the circuit G When not using the remote control unit breaker. for an extended period, remove the batteries to avoid possible leakage and damage to the unit.
  • Page 5: Operation

    OPERATION To Select Mode Operation Press the START / STOP button (Fig.6 M). The indoor unit’s OPERATION indicator lamp (red) (Fig. 3 5) will light. The air conditioner will start operating. Press the MASTER CONTROL button (Fig.6 H) to se- lect the desired mode.
  • Page 6 OPERATION About AUTO CHANGEOVER Operation G When AUTO CHANGEOVER operation first selected, the fan will oper- AUTO: ate at very low speed for about one minute, during which time the unit detects the room conditions and selects the proper operating mode. If the differance between thermostat setting and actual room tempera- ture is more than +4 °F →...
  • Page 7: Air Cleaning Operation

    AIR CLEANING OPERATION If you wish to eliminate dirt,dust,cigarette smoke, pollen, or just simply purify the air of the room, use the Air Cleaning Mode. Press the START/STOP button (Fig. 6 M). The operation indicator lamp will light up (red, as shown in the figure). (If the unit is already in operation, please proceed to step 2.) Press the AIR CLEAN button (Fig.
  • Page 8: Timer Operation

    TIMER OPERATION Before using the timer function, be sure that the Remote Control Unit is set to the correct current time, see page 4. To Use the ON timer or OFF timer To Cancel the Timer Press the START / STOP button (Fig. 6 M). Use the TIMER button to select “TIMER RESET.”...
  • Page 9: Sleep Timer Operation

    SLEEP TIMER OPERATION Unlike other timer functions; the SLEEP timer is used to set the length of time until air conditioner operation is stopped. To Use the SLEEP Timer While the air conditioner is operating or stopped, To Cancel the Timer: Use the TIMER button to select “TIMER press the TIMER button (Fig.
  • Page 10: Adjusting The Direction Of Air Circulation

    ADJUSTING THE DIRECTION OF AIR CIRCULATION Vertical (up-down) direction of airflow is adjusted by pressing the Remote Control Unit’s SET button. Horizontal (right-left) airflow direction is adjusted manually, by moving the Air Flow Direction Louvers. Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical air direction louvers are stopped.
  • Page 11: Swing Operation

    SWING OPERATION Begin air conditioner operation before performing this procedure. To select SWING Operation Press the SWING button (Fig. 6 P). The SWING indicator lamp (orange) (Fig. 3 8) will light. In this mode, the Air Flow Direction Louvers will swing automatically to direct the air flow both up and down.
  • Page 12: Cleaning And Care

    CLEANING AND CARE Before cleaning the plasma filter unit, be sure to turn off the power supply to the air conditioner. WARNING! Electric shock may result. G Make sure the plasma filter unit is properly mounted before cleaning or performing other tasks CAUTION! on it.
  • Page 13: Cleaning The Plasma Air Cleaning Filter

    CLEANING THE PLASMA AIR CLEANING FILTER Before cleaning the plasma filter unit, be sure to turn off the power supply to the air conditioner. WARNING! Electric shock may result. G Make sure the plasma filter unit is properly mounted before cleaning or performing other tasks CAUTION! on it.
  • Page 14: Install The Unit

    Cleaning the dust collection unit 4. Install the unit. 5. Install the air filter. G Please consult instructions for cleaning the air filter (The above figure is only for reference, so the intake grille is not included.) on page 12. 6.
  • Page 15 How to install or remove the Air- Air-cleaning and Deodorizing filter cleaning and Deodorizing filter maintenance As well as ensuring the maintenance of the dust collecting 1. Remove the dust-collecting unit. unit, please also take care of the filter. G Please consult steps 1 and 2 of cleaning the dust- (Please carry out maintenance on the filter every 6 months.) collecting unit on page 13.
  • Page 16: Troubleshooting

    TROUBLESHOOTING In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the WARNING! Power Supply Plug, and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source. Always be sure to disconnect the Power Supply Plug or turn off your circuit breaker to ensure that power is completely off.
  • Page 17: Auto Restart

    TROUBLESHOOTING Symptom Items to check See Page G Is the Power Supply Plug disconnected its outlet? CHECK ONCE Doesn’t operate at all: MORE G Has there been a power failure? — G Has a fuse blown out, or a circuit breaker been tripped? G Is the timer operating? 8 - 9 G Is the air filter dirty?
  • Page 18: Temperature And Humidity Range

    OPERATING TIPS Temperature and Humidity Range Cooling/Dry Mode Heating Mode Outdoor temperature About 32 to 115 °F About 17 to 75 °F Indoor temperature About 64 to 90 °F 88 °F or less About 80% or less If the unit is used for long pe- Outdoor temperature 68°F or obove riods under high-humidity...