Dometic 10 Series Installation Manual page 18

Absorber refrigerator
Hide thumbs Also See for 10 Series:
Table of Contents

Advertisement

Available languages

Available languages

Installing the refrigerator
If you have to use a roof vent instead of the air outlet vent:
➤ Cut out a section in the roof. Refer to the roof vent instruction manual for the
required dimensions. When doing so, observe the information in chapter
"Preparing the installation" on page 15.
5.4
Installing the ventilation grill
I
NOTE
Use exclusively original Dometic ventilation grills to ensure safe opera-
tion.
No. in
fig. 0, page 7
1
2
3
4
➤ Seal the installation frame to make the connection waterproof (fig. a, page 7).
➤ Insert the installation frame and screw it down tightly (fig. b, page 7). Use all the
fixing holes for this.
➤ Fit the ventilation grill (fig. c 1 – 2, page 8).
➤ Insert the slider and lock the ventilation grill with it (fig. c 3, page 8).
5.5
Installing condensation drain
I
NOTE
Condensation can form inside the refrigerator due to frequent door
opening, incorrectly stored food or food that is stored when it is too
warm.
Condensation must be drained with a constant slope.
Install the condensation drain as follows:
Variant 1:
➤ Run the condensation hose from the refrigerator through an opening in the floor
which goes outside under the vehicle.
18
Description
Slider
Ventilation grill
Installation frame
Fastening for condensation drain