Battery Charger Fault Codes - JLG X430AJ Operation And Safety Manual

Table of Contents

Advertisement

SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE

Battery Charger Fault Codes

(See "Errors Menu" on page 20 info for display information)
CODE
DESCRIPTION
Internal logic fault.
8
Communication problem with external memory.
13
Extended shutdown or power failure.
18
Internal logic fault.
19
Digital input is open and managed as hardware
240
start-stop.
Problem in CANBUS communication with other sys-
241
tems in the network.
Error when reading internal memory on micro con-
242
troller.
Mains voltage lower than maximum operating
244
range tolerance.
Abnormal current draw in primary section.
245
6-26
Table 6-13. Battery Charger Fault Codes
STATUS
Battery charger stops working.
Battery charger stops working.
Battery charger stops supplying power. Operation
resumes as soon as alarm conditions are no longer
present or after restarting.
Battery charger stops working.
Battery charger stops charging until digital input
closes.
The way this is managed may change based on dif-
ferent firmware releases.
Battery charger stops working.
Battery charger won't start charging until mains
voltage returns within normal operating range.
Battery charger stops supplying power. Operation
resumes as soon as alarm conditions are no longer
present.
– JLG Lift –
ACTION
Contact service dept. or change product.
Contact service dept. or change product.
If problem is a power failure, check battery charger
mains power supply.
Contact service dept. or change product.
Close digital input.
Check correct operation of CANBUS system.
Contact service dept. or change product.
Make sure mains voltage is within correct operating
parameters.
If problem persists, contact service dept. or change
product.
3121773

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents