7.3
Opening the burner
Disconnect the electrical supply from the burner
by means of the main system switch.
DANGER
Close the fuel interception tap.
DANGER
Wait for the components in contact with heat
sources to cool down completely.
RS 120/EV BLU
2
20086319
1
7.4
Closing the burner
Push the burner up to approximately 100 mm from the pipe
coupling.
Reconnect the cable and slide in the burner until it comes to
a stop.
Connect the plug of the servomotor and tighten the grommet
8).
Connect the socket of the maximum gas pressure switch.
Maintenance
Loosen the 4 screws 1)(Fig. 40) and remove the hood 2).
Assemble the two extensions supplied on the slide bars 4)
Disconnect the plug and unscrew the cable grommet 8).
Disconnect the socket from the maximum gas pressure
Remove the screws 3) and move the burner backwards by
Disconnect the electrode lead and then pull the burner fully
At this point it is possible to extract the inner part 5) after
6
4
1
3
8
7
RS 160-200/EV BLU
2
20086389
1
Replace the screws 3) and carefully pull the electrode cable
Disassemble the two extensions from the guides 4).
35
GB
(TL versions).
switch.
about 100 mm on the slide bars 4).
back.
having removed the screw 6).
5
4
1
6
7
outwards until it is slightly taut.
After carrying out maintenance, cleaning or
checking operations, reassemble the hood and all
the safety and protection devices of the burner.
6
5
3
8
Fig. 40
20085953