Contents Declarations....................................3 Information and general warnings............................5 Information about the instruction manual ........................5 2.1.1 Introduction.................................. 5 2.1.2 General dangers................................5 2.1.3 Other symbols ................................5 2.1.4 Delivery of the system and the instruction manual...................... 6 Guarantee and responsibility............................6 Safety and prevention................................
Page 4
Contents 6.4.1 Firing output ................................33 6.4.2 Maximum output ................................33 6.4.3 Minimum output .................................33 Final calibration of the pressure switches ........................34 6.5.1 Air pressure switch..............................34 6.5.2 Maximum gas pressure switch...........................34 6.5.3 Minimum gas pressure switch............................34 Visualisation and programming mode........................35 6.6.1 Normal mode ................................35 6.6.2 Info mode ...................................36 6.6.3...
Ridlerstrase, 65 80339 München DEUTSCHLAND CO max: 20 mg/kWh Measured value: NOx max: 67 mg/kWh Legnago, 21.05.2015 Executive General Manager Research & Development Director RIELLO S.p.A. - Burner Department RIELLO S.p.A. - Burner Department Mr. U. Ferretti Mr. F. Comencini 20068446...
Page 6
Declarations Manufacturer’s Declaration RIELLO S.p.A. declares that the following products comply with the NOx emission limits specified by German standard “1. BIm- SchV release 26.01.2010”. Product Type Model Power Forced draught gas burners 832T3 RS 55/E BLU 100 - 680 kW Legnago, 21.05.2015...
Information and general warnings Information and general warnings Information about the instruction manual 2.1.1 Introduction WARNING: MOVING PARTS The instruction manual supplied with the burner: This symbol indicates that you must keep limbs is an integral and essential part of the product and must not away from moving mechanical parts;...
Information and general warnings The system supplier must carefully inform the user about: 2.1.4 Delivery of the system and the instruction – the use of the system; manual – any further tests that may be required before activating the When the system is delivered, it is important that: system;...
Safety and prevention Safety and prevention Introduction The burners have been designed and built in compliance with the type and pressure of the fuel, the voltage and frequency of the current regulations and directives, applying the known technical electrical power supply, the minimum and maximum deliveries for rules of safety and envisaging all the potential danger situations.
The dimensions of the open burner are indicated by position O. Bear in mind that inspection of the combustion head requires the burner to be opened and the rear part drawn back on the guides. D3906 Fig. 1 RS 55/E BLU 255 - 390 2” Tab. E Blast tube: short-long Firing rate The maximum output is chosen within area A (Fig.
Technical description of the burner 4.7.1 Firing rate on basis of air density If H3 is greater than H1)(Fig. 3), the burner can produce the de- livery requested. The firing rate of the burner shown in the manual is valid for a If H3 is less than H1, it is necessary to reduce the output of the room temperature of 20°C and an altitude of 0m above sea level burner.
Technical description of the burner Test boiler The firing rates were obtained in special test boilers, according to The coupling is ensured when the boiler is EC type-approved; for EN 676 regulations. boilers or ovens with combustion chambers of very different di- mensions compared to those shown in the diagram of Fig.
Technical description of the burner 4.10 Burner description View from A D11480 Fig. 5 Combustion head 29 Flame stability disc Ignition electrode 30 Bracket for application of output power regulator RWF Screw for combustion head adjustment 31 Minimum gas pressure switch Pipe coupling Gas servomotor Plug-socket on ionisation probe cable...
To avoid accidents, material or environmental damage, observe the following instructions! The control box is a safety device! Avoid opening WARNING or modifying it, or forcing its operation. Riello S.p.A. cannot assume any responsibility for dam- age resulting from unauthorised interventions! Risk of explosion!
Page 17
Technical description of the burner The grounding of the burner must be in compliance with the Electrical connection of flame detector rules in force; the grounding of the boiler alone is not It is important for signal transmission to be almost totally free enough.
Page 18
Technical description of the burner Cable lengths – Main line AC 230 V Max. 100 m (100 pF / m) – Display, BCI For installation under the casing of the burner or in the control panel max. 3 m (100 pF / m) –...
Technical description of the burner 4.12 Operation sequence of the burner Operation Checking of Start up Shutdown seal TSA1 Phase number Timer - Resolution - Ratio 0.6s Timer 1 (parameters) Timer 2 (parameters) Timer 3 = max. phase time RAST plug Input signals PIN number Thermostat/pressure switch...
Technical description of the burner 4.12.1 List of phases Phase Description Phase Description Ph44 t44 = interval time 1 Ph00 Lockout phase Ph60 Operation Ph02 Safety phase Ph62 The burner moves to the switching off position Ph10 Closing paused Ph70 t13 = post-combustion time Ph12 Standby...
Technical description of the burner 4.13.2 Buttons description Button Button Function To regulate the fuel servomotor Button F (keep pressed and adjust the value by pressing To regulate the servomotor air Button A (keep pressed and adjust the value by pressing To modify the parameter for setting the P mode Button A and F VSD Function...
Technical description of the burner 4.14 Servomotors (SQM33..) Important notes To avoid accidents, material or environmental damage, observe the following instructions! Avoid opening, modifying or forcing the servo- WARNING motor. All interventions (assembly and installation operations, assistance, etc.) must be carried out by qualified personnel. ...
Installation Installation Notes on safety for the installation After carefully cleaning all around the area where the burner will The installation of the burner must be carried out be installed, and arranging the correct lighting of the environ- by qualified personnel, as indicated in this manual ment, proceed with the installation operations.
D455 Fig. 14 Blast tube Short (mm) Long (mm) RS 55/E BLU RS 55/E BLU 275 - 325 For boilers with front flue passes 13)(Fig. 17), a protection in re- Tab. J fractory material 11) must be inserted between the boiler refrac- tory 12) and the blast tube 10).
Installation Positioning probe - electrode Before fixing the burner to the boiler, check from the opening of the blast tube that the probe and the electrode are correctly positioned, as in WARNING Fig. 16. If, in the previous check, the position of the probe or electrode was not correct, is necessary: ...
Installation Securing the burner to the boiler Fix the flange 9) to the boiler plate, interposing the supplied insulating gasket 8). Provide an adequate lifting system of the burner. Use the 4 screws supplied, with a tightening torque of 35 - 40 Nm, after protecting their thread with anti-seize products.
Installation Combustion head adjustment At this stage of installation the blast tube and the pipe coupling are secured to the boiler as shown in A)(Fig. 18). Therefore the adjustment of the combustion head is particularly easy, an adjustment that depends solely on the maximum power of the burner.
Installation Burner closing refit the screws 2) and the split pin on the guides 3); Once the combustion head adjustment is completed: reassemble the burner on the guides 3)(Fig. 20) at about fix the burner to the pipe coupling with the screw 1). 100 mm from the pipe coupling 4) - burner in the position When fitting the burner on the two guides, it is ad- shown in Fig.
Installation 5.10 Gas feeding Explosion danger due to fuel leaks in the pres- ence of a flammable source. Precautions: avoid knocking, attrition, sparks and heat. Make sure that the fuel interception tap is closed before performing any operation on the burner. The fuel supply line must be installed by qualified personnel, in compliance with current standards and laws.
Installation 5.10.2 Gas train Type-approved in accordance with EN 676 and supplied sepa- rately from the burner. To select the correct model of the gas train, refer to the “burner- gas train combination” manual supplied. 5.10.3 Gas train installation D505 Disconnect the electrical power using the main system switch.
Page 31
Installation Example with natural gas G 20: Maximum output operation Gas pressure at test point 1)(Fig. 27) 10.4 mbar Pressure in combustion chamber 2.0 mbar 10.4 - 2.0 8.4 mbar A maximum output of 500 kW shown in Tab. K corresponds to 8.4 mbar pressure, column 1.
Installation 5.11 Electrical wiring Notes on safety for the electrical wiring The electrical wiring must be carried out with the electrical supply disconnected. Electrical wiring must be made in accordance with the regulations currently in force in the country of destination and by qualified personnel.
Installation 5.12 Calibration of the thermal relay The thermal relay is used to avoid damage to the motor owing to a strong increase in absorption or the lack of a phase. For the calibration, refer to the electrical wiring. If the minimum value of the scale of the thermal relay is greater than the rating absorption of the motor, protection is still ensured.
Start-up, calibration and operation of the burner Start-up, calibration and operation of the burner Notes on safety for the first start-up The first start-up of the burner must be carried out Check the correct working of the adjustment, com- by qualified personnel, as indicated in this manual mand and safety devices.
Start-up, calibration and operation of the burner As the burner is not fitted with a device to check the sequence of the phases, the motor rotation may be incorrect. As soon as the burner starts up, go in front of the cooling fan of the fan motor and check it is rotating anticlockwise.
Start-up, calibration and operation of the burner Final calibration of the pressure switches 6.5.1 Air pressure switch Adjust the air pressure switch (Fig. 32) after having performed all other burner adjustments with the air pressure switch set to the start of the scale. With the burner working at MIN output, insert a combustion analyser in the stack, slowly close the suction inlet of the fan (for example, with a piece of cardboard) until the CO value does not...
Start-up, calibration and operation of the burner Visualisation and programming mode 6.6.1 Normal mode 6.6.1.4 Condition error message, display of the errors and information The Normal mode is the standard operation mode visualised on the operator panel display. It is the main level of the menu. The display visualises alternately the error code (in the example ...
Start-up, calibration and operation of the burner 6.6.1.5 Reset procedure Releasing the key “ F ” the standard visualisation appears, with the current load percentage flashing: this means that the burner is The burner is in lockout when the red indicator light on the oper- working in Manual mode (any outside adjustment is excluded and ator panel is lit up, and the display visualises the lockout code (in only the safety devices are active).
Start-up, calibration and operation of the burner 6.6.3 Service mode 6.6.4 Parameter mode The Service mode ( SEr ) visualises the error log and certain The Parameters Mode ( PArA ) displays, and allows to be mod- technical information about the system. To access this level you ified/programmed, the list of parameters indicated on page 45.
Start-up, calibration and operation of the burner 6.6.4.2 Allocating the levels of the parameters The password must only be communicated to the The parameters' level is subdivided into groups as shown in Tab. qualified personnel or the Technical Assistance Service, and must be kept in a safe place. WARNING Parameter 100: ParA...
Page 41
Start-up, calibration and operation of the burner 6.7.0.1 Procedure for inserting and adjusting points on Select another point, or exit this area by pressing the keys “+” and “-” ( ESC ) simultaneously. the modulation curve Nine adjustment/calibration points (P1 ÷ P9) can be inserted in the control box for each servomotor, varying their position by de- grees and, consequently, the quantity of air and fuel introduced.
Start-up, calibration and operation of the burner Start-up procedure Check that the operator panel display shows the heat request Otherwise, modify the ignition point, see the section "Procedure and “OFF Upr” : this means it is necessary to set the modulation for inserting and adjusting points on the modulation curve"...
Page 43
Start-up, calibration and operation of the burner The control box will automatically report the same values set at Simultaneously press the keys “ + ” and “ - ” ( ESC ) twice, the dis- the points “ P0 ” and “ P1 ” to points “ P2 ” to “ P8 ”. play will show the position of the current load.
Start-up, calibration and operation of the burner Backup / Restore procedure At the end of the "Start-up procedure" it is opportune to make a We suggest carrying out this operation at the end backup, creating a copy of the data memorised on the REC, in of each intervention that modifies what has been the display panel RDI 21.
Start-up, calibration and operation of the burner NOTE: It is advisable to perform a backup every time If an error occurs during the backup process, the display that a parameter is changed, after checking screen shows a negative value. the modification carried out is correct. To determine the cause of the error refer to diagnostic code WARNING 137 (see section "Error codes list"...
Page 46
Start-up, calibration and operation of the burner The value 1 appears on the display screen: h min s After approx 8 seconds (it depends on the duration of the pro- gramme), the 0 value appears on the display screen, this is to in- dicate that the restore process has been completed correctly.
Start-up, calibration and operation of the burner 6.9.3 Parameter list Parameter Value range No. ele- Unit of Modifica- Degree of Default Acces mode ments measure tion accuracy setting Description Min. Max. INTERNAL PARAMETERS Start backup/restore process via RDI21... / PC TOOL (set the parameter to 1) Index 0 = create backup Modification...
Page 48
Start-up, calibration and operation of the burner Parameter Value range No. ele- Unit of Modifica- Degree of Default Acces mode ments measure tion accuracy setting Description Min. Max. Baud Rate for Modbus Values set: Modification Service mode 0 = 9600 1 = 19200 Parity for Modbus 0 = none...
Page 49
Start-up, calibration and operation of the burner Parameter Value range No. ele- Unit of Modifica- Degree of Default Acces mode ments measure tion accuracy setting Description Min. Max. Gas: selection of flame sensor 0 = QRB.../ QRC Modification Service mode 1 = ION / QRA Gas: Selection of the pre-purging function 0 = deactivated...
Page 50
Start-up, calibration and operation of the burner Parameter Value range No. ele- Unit of Modifica- Degree of Default Acces mode ments measure tion accuracy setting Description Min. Max. Position of the fuel servomotor in absence of flame Index 0 = standby position (°) Modification 0°...
Start-up, calibration and operation of the burner Parameter Value range No. ele- Unit of Modifica- Degree of Default Acces mode ments measure tion accuracy setting Description Min. Max. /h, l, h, Actual output Reading only 6553.5 Info mode /h, gal/h Status of external modules and visualisation Reading only Info mode...
Start-up, calibration and operation of the burner 6.14 Final checks (with burner operating) Open the thermostat/pressure switch TL The burner must stop Open the thermostat/pressure switch TS Turn the gas maximum pressure switch knob to the mini- ...
Maintenance Maintenance Notes on safety for the maintenance The periodic maintenance is essential for the good operation, safety, yield and duration of the burner. Disconnect the electrical supply from the burner It allows you to reduce consumption and polluting emissions and by means of the main system switch.
Maintenance Combustion If the combustion values found at the start of the intervention do not satisfy current standards or anyway indicate a poor state of combustion (consult the table below), contact the Technical As- sistance Service for the necessary adjustments. Air excess EN 676 Max.
Maintenance Opening the burner Loosen the screw 1)(Fig. 40) and remove the hood 2); disconnect the plug 14)(Fig. 17 at page 24), unscrew the Disconnect the electrical supply from the burner grommet 15); by means of the main system switch. ...
Faults - Probable causes - Solutions Faults - Probable causes - Solutions If faults arise in ignition or operations, the burner performs a In the event of a burner lockout, more than two "safety stop", which is signalled by the red burner lockout LED. consecutive burner reset operations could cause The display of the operator panel visualises alternately the lock- damage to the installation.
Page 57
Faults - Probable causes - Solutions Error Diagnostic code Meaning of the REC 27.100A2 system Recommended measures code The valve leak detection is active, but the minimum gas Valve leak detection test not possible pressure switch is selected as input for X9-04 (check parameters 238 and 241) The valve leak detection is active, but no input has been Valve leak detection test not possible...
Page 58
Faults - Probable causes - Solutions Error Diagnostic code Meaning of the REC 27.100A2 system Recommended measures code Carry out a reset; if the error arises repeatedly, replace the 50 ÷ 58 Internal error control box Carry out a reset; if the error arises repeatedly, replace the Internal error: no valid load checking device control box Carry out a reset;...
Page 59
Faults - Probable causes - Solutions Error Diagnostic code Meaning of the REC 27.100A2 system Recommended measures code Overloading of the servomotor or servomotor subjected to mechanical torsion. Bit 4 Deviation of section compared with the last reference 1. Check if the servomotor is blocked in any point along its Valence ...
Page 60
Faults - Probable causes - Solutions Error Diagnostic code Meaning of the REC 27.100A2 system Recommended measures code Insufficient mains voltage. Low level of power supply Conversion of the diagnostic code Voltage value (230 V AC : 1,683) Error code for the carrying out of a reset in the event of power Reset power supply voltage supply restoration (absence of error) Carry out a reset;...
Page 61
Faults - Probable causes - Solutions Error Diagnostic code Meaning of the REC 27.100A2 system Recommended measures code 254 (-2) Interruption owing to transmission error Repeat the reset and backup 255 (-1) Interruption owing to time-out during the restoration Carry out a reset, check the connections and repeat the backup Time-out of the system automation interface Refer to the Modbus User Documentation (A7541) Modbus time-out...
Page 62
Faults - Probable causes - Solutions Error Diagnostic code Meaning of the REC 27.100A2 system Recommended measures code Carry out a reset; if the error arises repeatedly, replace the Internal error control box Carry out a reset; if the error arises repeatedly, replace the Internal error control box Tab.
Appendix - Accessories Appendix - Accessories Long head kit Standard head length Extended head length Burner Code (mm) (mm) RS 55/E BLU 20040373 Spacer kit Burner Thickness (mm) Code RS 55/E BLU 3010129 Soundproofing chamber kit Burner Type dB(A) Code...
Page 64
Appendix - Accessories PVP kit (Pressure Valve Proving) Burner Gas train type Code RS 55/E BLU MB - CB 3010344 Gas trains in compliance with EN 676 Please refer to manual. 20068446...
Page 71
Appendix - Electrical panel layout Wiring layout key Control box for the air/fuel ratio 6 pin plug Operator panel 7 pin plug Filter to protect against radio disturbance Connector for operation without RWF output power regulator kit Burners components Connector for output power regulator kit RWF Boiler components 4 pole socket Output regulator RWF...