Bosch ICP-SOL2-P Quick Reference Manual page 34

Hide thumbs Also See for ICP-SOL2-P:
Table of Contents

Advertisement

3
en | Programming Parameters
Item
Event Code
Event Code
Polarity (Modes)
Time Base
Time Base Multiplier
Table 4.3: Output Item Options
* One Shot Mode
When you program the output polarity as one shot, the time base is multiplied by the time
base multiplier. (For example, if the time base = 2 and the multiplier = 05, the output operates
for 5 sec.)
*Pulsing Mode
When you program the output polarity as pulsing, the time base becomes the ON time and the
multiplier becomes the OFF time. The OFF time is the time base x the multiplier. (For
example, if you want the output to pulse 1 sec. ON and 5 sec. OFF, you would program time
base as one and the multiplier as five.)
2014.06 | 02 | F01U298027
Option
4 0 = Reserved
4 1 = Reserved
4 2 = Reserved
4 3 = Reserved
4 4 = Reserved
4 5 = Chime
4 6 = Zone not sealed
4 7 = Zone not sealed after Exit Time
4 8 = Reserved
4 9 = AC MAINS cycle (60 Hz or 50 Hz)
4 10 = Area 1 – zone unsealed
4 11 = Area 2 – zone unsealed
4 12 = Reserved
4 13 = Reserved
4 14 = Reserved
4 15 = Reserved
6 0 = Reserved
6 1 = Reserved
6 2 = Remote control 4
6 3 = Remote control 5
6 4 = Remote control 6
6 5 = Remote control 7
0 = Output not used
1 = Normally open, going low
2 = Normally open, pulsing low
3 = Normally open, one shot low
4 = Normally open, one shot low (reactivate)
5 = Normally open, one shot low (can reset)
6 = Normally open, one shot low (alarm)
7 = Normally open, latching low
0 = Not Used
1 = 200 ms
2 = 1 sec.
Enter a value between 00 and 99.
5 0 = Reserved
5 1 = Reserved
5 2 = Area 1 in alarm
5 3 = Area 2 in alarm
5 4 = Reserved
5 5 = Reserved
5 6 = Area 1 armed
5 7 = Area 2 armed
5 8 = Reserved
5 9 = Reserved
5 10 = Area 1 disarmed
5 11 = Area 2 disarmed
5 12 = Reserved
5 13 = Reserved
5 14 = Any areas armed
5 15 = Any areas disarmed
6 6 = Remote control 8
6 7 = Remote control 9
6 8 = Remote control 10
6 9 = Remote control 11
6 10 = Remote control 12
8 = Normally low, going open
9 = Normally low, pulsing open
10 = Normally low, one shot open
11 = Normally low, one shot open
(reactivate)
12 = Normally low, one shot open (can
reset)
13 = Normally low, one shot open (alarm)
14 = Normally low, latching open
3 = 1 min.
4 = 1 hr.
Quick Reference Guide