3 - PROGRAM LEVEL #2
RESERVE CAPACITY (
Not viewed in timeclock regeneration mode.
Press the button
. This parameter is identified by the letters "rc". This display shows the
reserve capacity calculated by the electronic for the present day. This display is used as an aid
in the valve maintenance and is not an option setting. The unit of measure used depends on the
display format chosen
(1)
.
Ex.: 24,6 m
3(1)
PREVIOUS DAYS WATER USAGE (P
Not viewed in timeclock regeneration mode.
Press the button
. This display is identified by the letters "Pd". This display shows the previous
days water usage recorded. This display is used as an aid in the valve maintenance and is not
an option setting. The unit of measure used depends on the display format chosen
Ex.: 28,4 m
3(1)
LOCATION FOR CHLORINATION INDICATOR (J):
Not viewed in RM version (Remote Meter).
Press the button
. This display is identified by the letter "J". This display is used to set the
desired regene-ration cycle number where the chlorinating indicator will turn on in the
regeneration display. This parameter does not command the chlorinator whom has to be handled
by a microswitch or by a time auxiliary output.
Ex.: No chlorinator installed
Chlorinator to turn on during the cycle 2
Note: During a regeneration with the chlorinating indicator set, for example cycle 2,
the regeneration display will show:
Timed auxiliary output programming (y) (r) (n):
See points 2.7, 2.8 and 2.9
Press the button
. The next three display viewed are part of a series of option setting used to
program the auxiliary relay output. The first two settings ("y" and "r") turn the output on / off during
regeneration only.
Two independent signals can be programmed for the same output during regeneration. The third ("n")
turns the output on during the service only, when a set volume of water used has accumulated and
for a set duration.
Note: when more than one of these settings are used, it will be up to the softener manufacturer to
supply the switching logic necessary to operate two or three of device of equipment at a time from
a single relay output.
(1)
The unit of measure depends on the display format chosen.
All examples above are based on the cubic meter format (see point 2.12).
rc
):
d
):
[rc - - 24.6]
(1)
.
[Pd - - 28.4]
[J- - - OFF]
[J- - - - - -2]
[2C - - 38.2]
3200 ET & RM