Switches:
Description of the switches in order - front to back:
Red Toggle Switch: Main unit power.
Blue Toggle Switch: LED lighting (will only turn on if the 3D Printer is on via the red
rocker switch).
Emergency Stop Switch: Kills all power to the unit in the case of an emergency. If
the button is pressed down, then emergency stop is engaged. To disengage simply
turn the red button clockwise and the button will disengage. If your unit fails to
turn on, it is highly likely this switch is engaged.
Fused Power Switch: This switch is fused and controls the flow of power from the
wall to the red toggle switch. This blue rocker switch needs to light up to indicate
power is flowing to the main power switch, the red toggle switch. Inside the fused
power switch you will find a F10AL250V fuse that is designed to protect the
wiring. These are commonly sold on Amazon and eBay, unfortunately, local
hardware and automotive stores do not carry these.