16mm Shaft Collar – Four Total:
With the shaft collars loosened and dropped to the bottom, we need to
level the aluminum bed. This is done by holding the bubble level underneath the
aluminum bed with one hand, and using the other to manually turn a ballscrew (Z
axis) to bring it in line. Our ICARUS units will self level themselves, however we
need to check that the current level state is in an acceptable range.
Bubble Level Under the Aluminum Plate: