Download Print this page

ClearSpan 107764 Instruction Manual

20' wide free-standing building

Advertisement

Quick Links

©2019 ClearSpan™
All Rights Reserved. Reproduction
is prohibited without permission.
Revision date: 05.20.19
ClearSpan
20' Wide Free-Standing Building
Photo may show a different but similar model.
CLEARSPAN
STK#
107764
107765
POLY BUILDINGS
DIMENSIONS
20' W x 12' H x 20' L
20' W x 12' H x 40' L
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the 107764 and is the answer not in the manual?

Questions and answers

Summary of Contents for ClearSpan 107764

  • Page 1 ClearSpan ™ 20' Wide Free-Standing Building Photo may show a different but similar model. STK# DIMENSIONS 107764 20' W x 12' H x 20' L ©2019 ClearSpan™ All Rights Reserved. Reproduction 107765 20' W x 12' H x 40' L is prohibited without permission.
  • Page 2: Safety Precautions

    • Never erect the structure under power lines. • Identify whether underground cables and pipes are Thank you for purchasing this ClearSpan™ shelter. When present before preparing the site or anchoring the properly assembled and maintained, this product will structure.
  • Page 3: Assembly Procedure

    These words and phrases are common to most straight ends of other pipes of the same diameter. ClearSpan™ shelters and identify the different parts of • Tek Screw: A self-tapping fastener used to secure pipe the shelter.
  • Page 4: Required Tools

    CLEARSPAN POLY BUILDINGS ™ REQUIRED TOOLS SPECIAL NOTE: Boards for Frame Assembly The following list identifies the main tools needed to These instructions recommend installing a board under the assemble the shelter. Additional tools and supports may be base plates along each side of the frame. The board runs needed depending on the structure, location, and from front to the back of the building.
  • Page 5 CLEARSPAN POLY BUILDINGS ™ The following graphics and photos will help you identify the different parts of the building. Consult the Quick Start Guide for additional details and diagrams. (All parts are not shown.) ASSEMBLY NOTE: Install Tek screws using a clutched drill driver running approximately 750 RPM while applying approximately 50 lbs of force.
  • Page 6 CLEARSPAN POLY BUILDINGS ™ ClearSpan ™ Free-Standing Building The instructions that follow describe assembling all rafters and then constructing the frame. Depending on the number of individuals assisting with the construction, it may be best and more efficient to have someone assemble the rafters and others assemble the frame as rafters are completed.
  • Page 7 CLEARSPAN POLY BUILDINGS ™ LAY OUT THE BUILDING SITE NOTE: Setting customer-supplied boards on the site in the correct positions is another way to prepare for After the site is prepared, identify the location of the shelter frame assembly. corners to help square the frame after it is assembled.
  • Page 8 CLEARSPAN POLY BUILDINGS ™ ASSEMBLING THE RAFTERS 1. Select the six (6) pipes needed to assemble a rafter and arrange these on a flat surface as shown below. NOTE: Assistance is required to assemble rafters. Gather parts: • Round pipe: rafter position #1 (#20R1601)
  • Page 9 CLEARSPAN POLY BUILDINGS ™ RAFTER ASSEMBLY (CONTINUED) END RAFTER ASSEMBLY In addition to the steps in the previous procedure, complete the following steps for two (2) end rafters only. Rafter Pipe 1. Take one of the remaining assembled rafters and place it on a flat surface.
  • Page 10: Frame Assembly

    CLEARSPAN POLY BUILDINGS ™ FRAME ASSEMBLY 3. Using the on-center, rafter-to-rafter spacing, set an inside rafter in position. (Additional assistants are Gather the parts: required to hold the inside rafter in position.) See Side Profile diagrams for the correct rafter spacing.
  • Page 11 CLEARSPAN POLY BUILDINGS ™ FRAME ASSEMBLY (CONTINUED) If the last end rafter is plumb and the purlin run extends beyond the end of the rafter, cut the last section of 8. Move to the lower end of the rafters, verify that the purlin pipe to the required length.
  • Page 12 CLEARSPAN POLY BUILDINGS ™ FRAME ASSEMBLY (CONTINUED) 2. Verify that the width of each rafter is 20' center-to- center. The frame is square when the two diagonal 2. Remove the bolts and attach a strut between the band measurements are the same. See previous diagram.
  • Page 13 CLEARSPAN POLY BUILDINGS ™ PREPARE MAIN COVER These cover conduits are inserted into the pockets sealed to the main cover. The cover conduits are used Gather the parts: to tighten and secure the main cover. • Ratchet (1") 3. After assembling the cover conduits, locate the main cover and unfold it on a clean, smooth surface near the •...
  • Page 14 CLEARSPAN POLY BUILDINGS ™ PREPARE MAIN COVER (CONTINUED) 5. Divide the remaining number of ratchets in half. Place the ratchets on the ground next to the rafter where they NOTE: Depending on the length of the cover it may will be attached.
  • Page 15 NOTE: With the exception of Truss Arch buildings, ClearSpan™ shelters and greenhouses do not have any 13. Fold the skirt of main cover down to complete the tested loading criteria.
  • Page 16 CLEARSPAN POLY BUILDINGS ™ 12'-8" QUICK START GUIDE 20' Wide Free-Standing Building 20'-0 5/8" on-center width 20'-6 1/8" outside-to-outside FRONT Grid Represents 12" Squares Frame shown may differ in length from actual frame. 107764_65 Revision date: 05.20.19...
  • Page 17 CLEARSPAN POLY BUILDINGS ™ Revision date: 05.20.19 107764_65...
  • Page 18 CLEARSPAN POLY BUILDINGS ™ 107764_65 Revision date: 05.20.19...
  • Page 19 CLEARSPAN POLY BUILDINGS ™ Revision date: 05.20.19 107764_65...
  • Page 20 CLEARSPAN POLY BUILDINGS ™ 107764_65 Revision date: 05.20.19...
  • Page 21 CLEARSPAN POLY BUILDINGS ™ Revision date: 05.20.19 107764_65...

This manual is also suitable for:

107765