Terminal Designations - ABB RTAC-01 User Manual

Pulse encoder interface module
Table of Contents

Advertisement

Chapter 3 – Installation
Terminal
designations
X1 Marking Description
1
0 V
2
0 V
3
V OUT
4
+15V
5
V IN
6
+24V
X2
Marking Description
1
SHLD
2
SHLD
3
A+
4
A-
5
B+
6
B-
7
Z+
8
Z-
3-2
Encoder power supply, either 15 or 24 V DC (according
to jumper selection on terminals 4, 5 and 6).
(0 V is also used with single-ended encoder connection
for balancing the A+, B+ and/or Z+ conductors. See
Figures
Encoder supply voltage selection:
Terminals 4 and 5 connected: 15 V (default)
Terminals 5 and 6 connected: 24 V
(Jumper is supplied with the RTAC module)
Max. 5 watts (see
Connected internally on the circuit board.
For earthing of the encoder cable shields. Internally
Shield
connected to the frame.
• Max. signal frequency: 200 kHz
A
• Signal levels:
A
"1" > 7.6 V, "0" < 5 V (for 15 V supply)
"1" > 12.2 V, "0" < 8 V (for 24 V supply)
B
• Input channels isolated from the logic, power supply,
and earth
B
• When the drive runs in the Forward direction,
channel A should lead channel B by 90° (electrical)
Z
• Channel Z: One pulse per revolution (used in
Z
positioning applications only)
3-3
to 3-6.)
Power consumption
below)
RTAC-01 User's manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents