For mounting the IS 3180 on the wall, a condensation water drainage hole (Ø 5 mm
drill bit) is marked next to the rubber seal. This must be opened if necessary.
Connection examples (Fig. 4.2)
a Light without neutral conductor
b Light with neutral conductor
c Connection by means of two-circuit single-interruption switch for
manual and automatic operation
d Connection via two-way switch for manual override and automatic operation
Setting I: Automatic operation
Setting II: Manual operation, light permanently ON
Note:
The system cannot be switched OFF, it is only possible to select operation
via setting I or II.
a) Load, lighting max. 2000 W (refer to Technical specifications)
b) Sensor connection terminals
c) Indoor switch
d) Indoor two-circuit single-interruption switch, manual, automatic
e) Indoor two-way switch, automatic, light permanently ON
Connecting several sensors in parallel (not illustrated)
In this case, it is important not to exceed a sensor's maximum connected rating. In
addition, all units must be connected to the same phase. As many as 10 sensors can
be connected in parallel.
Note:
The cable between two sensors must be no more than 50 m in length.
5. Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• Select an appropriate mounting location, taking the reach and motion detection
into consideration.
Procedure for installing concealed power supply lead (Fig. 5.1)
Procedure for installing surface-mounted power supply lead (Fig. 5.2)
IS 3360, IS 3360 MX Highbay, IS 345, IS 345 Highbay
Procedure for installing concealed power supply lead (wall mounting) IS 3180
(Fig. 5.3)
28
• Switch OFF power supply.
• Detach designer trim from sensor module.
• Disconnect sensor module from the load module.
• Connect to mains power supply.
– Surface-mounted power supply lead (Fig. 5.4)
– Concealed power supply lead (Fig. 5.5)
• Insert fastening screw and mount load module.
Limiting reach
The detection zone can be optimised to suit requirements.
– By adjusting the lens. (Fig. 5.8 / 5.10)
– By using the half-round clip-on shroud. (Fig. 5.11)
Note:
To limit reach, the sensor module must be detached from the load module.
• To activate the required reach, undo the screws or completely remove them.
• Move lens into required zone.
• The half-round clip-on shroud provided can be used for masking out any number
of lens segments to shorten reach as required.
• Afterwards, fix the lens in place with the screws.
Detection zone/reach
IS 3360 (Fig. 5.6)
IS 3360 MX (Fig. 5.7)
Mounting height
Reach (tangential)
14 m
10 m
9 m
14 m
6 m
16 m
2.8 m
18 m
IS 345 (Fig. 5.8)
IS 345 MX (Fig. 5.9)
Mounting height
Reach (tangential)
14 m
30 m × 4
10 m
25 m × 4
8 m
20 m × 4
6 m
15 m × 4
4 m
10 m × 4
29