Mounting; Control Units - Siemens SIMATIC ET 200pro Manual

Migration
Hide thumbs Also See for SIMATIC ET 200pro:
Table of Contents

Advertisement

Migration SIMATIC ET 200pro FC 108869725
Figure 15

Mounting

The new Pro-2 Power Modules can be fitted on the same mounting backplane
accessory as before. There are no changes in the mounting arrangements
2.3

Control Units.

The control unit (CU) of the ET 200pro FC and ET 200pro FC-2 are integrated into
the Power Module. All hardware is within the IP65 casing when delivered.
However, ET 200pro FC was based on GP Pool software (similar to MM4) whereas
ET 200pro FC-2 firmware is based on SINAMICS Pool. (eg. G120D)
Therefore the Power Modules are not directly interchangeable due to the
differences in CU Firmware.
NOTE
The ET 200pro FC Header Modules are typically IM154-2 DP or IM154-2 PN for
Profibus or Profinet interfacing..