4.
Assemble the cable and line entry as displayed in figure 4 "Cable and line entry".
The adapter (1) must not be removed for connection of the connection lines.
– Slide the screw-in bushing (5), seal ring (3) and pressure rings (4) onto the line
(a), insert it via the adapter (1) into the terminal box (b) and firmly tighten (c)
the screw-in bushing (5).
– Assemble the clamping collar (6) for strain relief of the connection line and
firmly tighten it all (d).
5.
Screw in the clamping screws to fix the line ends.
Tightening torques for the clamping screws:
Table 14: Tightening torques
Operating voltage connection
Connection for protective grounding conductor (inside)
Connection for potential equalization conductor (outside)
6.
Place the O-ring into the groove of the terminal box and assemble the cover.
Tighten the mounting screws with the spring washers diagonally, one after the
other. Tightening torque of the cover screws: 2...2.2 Nm.
When replacing the cover mounting screws, only the screws supplied in the spare
parts kit (seal kit terminal box) may be used, see chapter 10.6 "Spare parts".
0.4...0.45 Nm
1.0...1.2 Nm
2.0...2.4 Nm
RE22047-XD-B/02.19, M-.SE 6 ...XD..., Bosch Rexroth AG
Assembly
35/52