Operating The Manual Override - Bosch Rexroth M SE 6 XD Series Operating Instructions Manual

Directional seat valves, direct operated, with solenoid actuation
Table of Contents

Advertisement

9.2 Operating the manual override

Danger of damage to property!
Uncontrolled operation of the manual override bears the danger of damaging
the system!
Only operate the manual override if it is ensured that this will not trigger any
dangerous working movement of the connected actuator.
Only operate the manual override when the pressure in the tank channel does
not exceed 50 bar. Above this pressure value, the actuating force to be applied
is too large.
Do not use sharp-edged tools to operate the manual override.
The valves are equipped with a manual override. Using this manual override, the
switching function of the valve can also be triggered if the solenoid is not energized.
The manual override is only intended for manual operation. It is not suitable for
frequently recurring manual operations!
The manual override is located on the side of the valve solenoid facing away from
the valve.
NOTICE
RE22047-XD-B/02.19, M-.SE 6 ...XD..., Bosch Rexroth AG
Operation
39/52