Advantech PCM-9562 User Manual page 62

Table of Contents

Advertisement

SMBus
When the application has executed, you can click the radio button to choose to test
each access mode, i.e. Access a byte, Access multiple bytes and Access a word. All
data must be read or written in hexadecimal except the numbers for radio button:
Access multiple bytes mode must be written in decimal. You can test the functional-
ities of the watchdog as follows:
Read a byte
Click the radio button- Access a byte.
Key in the slave device address in the Slave address field.
Key in the register offset in the Register Offset field.
Click the READ SMBus DATA button and a byte of data from the device will
be shown on the Result field.
Write a byte
Click the radio button- Access a byte.
Key in the slave device address in Slave address field.
Key in the register offset in Register Offset field.
Key the desired data in the Result field to write to the device.
Click the WRITE SMBus DATA button and then the data will be written to the
device through SMBus.
Read a word
Click the radio button- Access a word.
Key in the slave device address in the Slave address field.
Key in the register offset in the Register Offset field.
Click the READ SMBus DATA button and then a word of data from the device
will be shown on the Result field.
Write a word
Click the radio button- Access a word.
Key in the slave device address in the Slave address field.
Key in the register offset in the Register Offset field.
Key in the desired data, such as 0x1234, in the Result field to write to the
device.
Click the WRITE SMBus DATA button and the data will be written to the
device through the SMBus.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com