OBJ_BUCH-2326-003.book Page 27 Thursday, August 20, 2015 8:43 AM
in direct vicinity being harmed cannot be completely exempt. Do not use the
measuring tool with
tions, chemical plants, areas where there is danger of explosion, and areas
subject to blasting. Do not use the measuring tool with
planes. Avoid operation in direct vicinity of the body over longer periods.
Do not use the measuring tool if the touchscreen is visibly damaged (e.g.
cracks in the surface etc.).
The
® word mark and logos are registered trademarks owned by Blue-
tooth SIG, Inc. and any use of such marks by Robert Bosch GmbH is under li-
cense.
Product Description and Specifications
Intended Use
The measuring tool is intended for measuring distances, lengths, heights, clearances
and inclines, and for calculating areas and volumes.
The measuring results can be transferred to other devices via Bluetooth®.
The help function integrated into the measuring tool provides detailed animations
about individual measuring functions/procedures.
Technical Data
Digital Laser Measure
Article number
Distance measurement
Measuring range
Measuring accuracy (typical)
Lowest indication unit
Inclination measurement
Measuring range
Measuring accuracy (typical)
Lowest indication unit
General
Operating temperature
Storage temperature
Relative air humidity, max.
Bosch Power Tools
® in the vicinity of medical devices, petrol sta-
0°–360° (4x90°)
–10 °C...+50 °C
–20 °C...+70 °C
1 609 92A 1F3 | (20.8.15)
English | 27
® in air-
PLR 50 C
3 603 F72 2..
A)
0.05–50 m
B)
±2.0 mm
0.1 mm
C)/E)
±0.2°
0.1°
D)
90 %