serial device can also receive data from one or multiple host
Label
Listen Port
Host start IP/end IP
Send Port
RTU/ASCII Slave Mode
Modbus RTU Slave mode allows communications between a host computer and a slave
device. After a host computer sends a command, the slave device processes the
command and returns a response to the host computer. This process is repeated,
allowing the host computer to monitor and control controller operation. Modbus ASCII
Slave mode works the same as Modbus/RTU Slave mode, except that the data format is
Modbus/ASCII.
ORing Industrial Networking Corp.
Description
Allows the user to set a new TCP port number to listen on rather than
the default value of the device
If there are more than one destination hosts, specify the IP address
range by inputting a value in Host Start / End IP. You can also auto
scan the sending port number of the device
Set the send port number.
IGMG-P83244GC+-D4G
User Manual
29