ORiNG IMG-111 Series User Manual

ORiNG IMG-111 Series User Manual

Industrial m2m gateway
Hide thumbs Also See for IMG-111 Series:

Advertisement

Quick Links

I
M
G
-
1
1
I
M
G
-
1
1
I
n
d
u
s
t
r
i
a
l
M
I
n
d
u
s
t
r
i
a
l
M
U
s
e
r
U
s
e
r
V
e
r
s
V
e
r
s
J
u
l
y
J
u
l
y
1
S
e
r
i
e
s
1
S
e
r
i
e
s
2
M
G
a
t
e
w
2
M
G
a
t
e
w
M
a
n
u
a
l
M
a
n
u
a
l
i
o
n
2
.
0
i
o
n
2
.
0
,
2
0
1
4
,
2
0
1
4
w
w
w
.
o
r
w
w
w
.
o
r
a
y
a
y
i
n
g
-
n
e
t
w
o
r
k
i
n
g
.
c
o
m
i
n
g
-
n
e
t
w
o
r
k
i
n
g
.
c
o
m

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IMG-111 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ORiNG IMG-111 Series

  • Page 2 ORing warrants that all ORing products are free from defects in material and workmanship for a specified warranty period from the invoice date (5 years for most products). ORing will repair or replace products found by ORing to be defective within this warranty period, with shipment expenses apportioned by ORing and the distributor.
  • Page 3: Table Of Contents

    IMG-111-2G User’s Manual Tables of Contents Getting Started ....................1 About the IMG-111 Series ..................... 1 Software Features ......................1 Hardware Features ......................1 Hardware Overview ..................2 Front Panel ........................2 Front Panel LED ......................3 Hardware Installation ..................4 DIN-Rail Installation .......................
  • Page 4 Reboot Device ......................41 5.3.6 Serial Settings ......................42 5.3.7 Service Mode ......................43 Virtual COM Mode ......................43 TCP Server Mode ....................... 45 TCP Client Mode ........................ 46 UDP Mode .......................... 48 Technical Specifications ..............49 ORing Industrial Networking Corp.
  • Page 6: Getting Started

    IMG-111 User’s Manual etting Started 1.1 About the IMG-111 Series The IMG-111 series M2M Gateway is designed to operate industrial environment, allowing devices communicate with the Internet rapidly and efficiently over the LAN. The series consists of the IMG-111 and IMG-111-2G models to meet customers’...
  • Page 7: Hardware Overview

    SIM card slot 1 x antenna connector Antenna connector 1. Fault LED. . 2. Status LED 3. Power LED 4. WAN LED 5. Serial transmission LED 6. RS-232 Serial port 7. 10/100Base-T(X) RJ45 fast Ethernet port ORing Industrial Networking Corp.
  • Page 8: Front Panel Led

    Power On. Device is ready Status Green Blinking Booting up WAN connection fails (enable event Fault Amber through web) Modem is ready Green Blinking Checking modem status Amber Port speed at 10Mbps Green Port speed at 100Mbps ORing Industrial Networking Corp.
  • Page 9: Hardware Installation

    Step 1: Install the L-shape mounting kits provided in the package to the left and right of the device. Step 2: With front brackets orientated in front of the rack, mount the device in the rack with four rack-mounting screws. ORing Industrial Networking Corp.
  • Page 10: Sim Card Installation

    Note: only remove the cover for SIM card installation. DO NOT remove the cover in normal operation. 3. Insert the SIM card into the slot. 4. Put the cover back 5. Fasten the screws. Note: Make sure the power is off before you install the SIM card. ORing Industrial Networking Corp.
  • Page 11: Cables And Antenna

    The device supports auto MDI/MDI-X operation. You can use a cable to connect the switch to a PC. The table below shows the 10/100Base-T(X) MDI and MDI-X port pin outs. 10/100 Base-T(X) MDI/MDI-X Pin Assignments: Pin Number MDI port MDI-X port TD+(transmit) RD+(receive) TD-(transmit) RD-(receive) RD+(receive) TD+(transmit) Not used Not used ORing Industrial Networking Corp.
  • Page 12: Wireless Antenna

    Note: “+” and “-” signs represent the polarity of the wires that make up each wire pair. 4.2 Wireless Antenna A GSM/DCS/UMT antenna is used for the built-in modem. You can also use an external RF cable and antenna for this connector. Cellular Antenna ORing Industrial Networking Corp.
  • Page 13: Management

    A login window will pop up where you can enter the default login name admin and password admin. For security reasons, we strongly recommend you to change the password. Click on System Tools > Login Setting after logging in to change the password. ORing Industrial Networking Corp.
  • Page 14: Configuration

    Wan IP Shows WAN IP address 5.2.1 Basic Setting This section will guide you through the general settings for the device. This page allows you to configure WAN settings. Different WAN connection types will have different settings. ORing Industrial Networking Corp.
  • Page 15: Lan

    Enable auto refresh modem status per 28 sec These are the IP settings of the LAN interface for the IMG-111 M2M Gateway. The LAN IP address is privately for your internal network and cannot be exposed on the Internet. ORing Industrial Networking Corp.
  • Page 16: Dhcp

    Enables or disables the DHCP server function. The default setting is Enabled. Starting IP The starting IP address of the IP range assigned by the DHCP server Ending IP The ending IP address of the IP range assigned by the DHCP server ORing Industrial Networking Corp.
  • Page 17: Ip Allocation

    Static DHCP Client List Shows the IP addresses locked to specific MAC addresses 5.2.2 Serial Setting Remote management The remote management setting allows user to enable the WAN access of the DS-tool management and serial port access. ORing Industrial Networking Corp.
  • Page 18: Serial Configuration

    Enable to managed IMG-111 by DS-tool through WAN access Management Port External Enable to allow using of serial data port and control port through Access WAN access l Serial Configuration This page allows you to configure serial port parameters. ORing Industrial Networking Corp.
  • Page 19: Port Configuration

    The received data will be queued in the buffer until all the delimiters are Serial to matched. When the buffer is full (4K Bytes) or after "flush S2E data Ethernet buffer" timeout, the data will also be sent. You can set the time from 0 to 65535 second. ORing Industrial Networking Corp.
  • Page 20: Service Mode

    0 indicate disable this function. Factory default value is 0. If Multilink is configured, only the first host connection is effective for this setting. Alive Check The serial device will send TCP alive-check package in each ORing Industrial Networking Corp.
  • Page 21: Tcp Server Mode

    The serial device will send TCP alive-check package in each Alive Check defined time interval (Alive Check) to remote host to check the TCP connection. If the TCP connection is not alive, the ORing Industrial Networking Corp.
  • Page 22: Tcp Client Mode

    The serial device will send TCP alive-check package in each defined time interval (Alive Check) to remote host to check the Alive Check TCP connection. If the TCP connection is not alive, the connection will be closed and the port will be freed. 0 indicate ORing Industrial Networking Corp.
  • Page 23: Udp Client Mode

    Local port will be redirected to the computer specified by the Local IP. Any PC that was used for a virtual server must have static or reserved IP Address because its IP address may change when requesting IP by DHCP ORing Industrial Networking Corp.
  • Page 24 Some applications require multiple connections, like Internet games, video conferencing, Internet calling and so on. These applications cannot work with a pure NAT M2M Gateway. Port Trigger is used for some of the applications that can work with an NAT M2M Gateway ORing Industrial Networking Corp.
  • Page 25 To use this function, you need to set an internal computer as the DMZ host by entering its IP address. Adding a client to the DMZ may expose your local network to a variety of security risks, so use this function carefully. ORing Industrial Networking Corp.
  • Page 26 Application: The application that generates this port forwarding. Ext Port: The port opened on WAN Protocol: The protocol type Int Port: The port redirected to the local computer IP Address: The IP address of local computer to be redirected to ORing Industrial Networking Corp.
  • Page 27: Security Setting

    IP Filter List Click edit for editing the entry, click Del to delete the entry. MAC Filter This page enables you to deny or allow LAN computers to access the Internet based on their MAC addresses. ORing Industrial Networking Corp.
  • Page 28: Vpn Setting

    Open VPN Open VPN is a full-functioned SSL VPN solution which can accommodates a wide range of configurations including remote access, site-to-site VPNs, WiFi security, and enterprise-scale remote access solutions with load balancing, failover, and fine-grained access-controls. ORing Industrial Networking Corp.
  • Page 29 1: Open VPN Server Connection to Open VPN Server Before connecting to the Open VPN server of IMG-111 M2M Gateway, please install Open VPN client software for your windows PC. It can be downloaded from http://Open ORing Industrial Networking Corp.
  • Page 30 Enables or disables the LZO Compression Keys Setting Select Auto to use preset certificates or Manual to use your certificates. Please install openvpn client software to generate your certificates and paste them here. For more information, please visit openvpn website. ORing Industrial Networking Corp.
  • Page 31 IP and Client IP address should configure with the same network domain. PPTP VPN PPTP (Point to Point Tunneling Protocol) VPN allows PCs connected to the router through WAN ports to act as PCs in the same LAN. ORing Industrial Networking Corp.
  • Page 32 Enables or disables PPTP VPN server Server IP Enter the server IP address. The default value is the IP address of the connected LAN port. Client IP Enter the IP address range in the form of 192.168.10.xx-xx. The ORing Industrial Networking Corp.
  • Page 33 Enter the username and password pairs in the form of user * pass *. Multiple username and password pairs are allowed. PPTP Client If a router wants to link to the device in different networks, you should enable PPTP client in the following page. ORing Industrial Networking Corp.
  • Page 34: Routing Protocol

    Encryption) encryption on data transmitted through PPP (Point-to-Point Protocol) and VPN links. Click Connect to link to the server or Disconnect to disconnect from the Operations server Link Status Show the status of the link Routing Protocol Routing Setting ORing Industrial Networking Corp.
  • Page 35 BGP; however, the device only supports RIP (Routing Information Protocol). Do not choose Disable in the RIPv1 & v2 list if you want to enable Dynamic Routing. After clicking Apply, more information will be displayed in Current Routing Table. ORing Industrial Networking Corp.
  • Page 36 Choose Disable to disable dynamic routing or other options to configure the interfaces for dynamic routing Telnet Setting This option is only available when dynamic routing is enabled. It allows you to make detailed configurations via simple comments. ORing Industrial Networking Corp.
  • Page 37: Miscellaneous

    DDNS (Dynamic Domain Name System) allows you to configure a domain name for your IP address which is dynamically assigned by your ISP. Therefore, you can use a static domain name that always points to the current dynamic IP address. ORing Industrial Networking Corp.
  • Page 38: System Tools

    In this page, you can set the date & time of the device. A correct date and time will help the system log events. You can set up a NTP (Network Time Protocol) client to synchronize date & time with a NTP server on the Internet. ORing Industrial Networking Corp.
  • Page 39: System Event

    When the WAN Link Down option is enabled, the system will notify you when the link is down. Login Setting You can change login name and password in page. The default login name and password are both admin. ORing Industrial Networking Corp.
  • Page 40: M2M Gateway Restart

    M2M Gateway Restart If you want restart the M2M Gateway through the Warm Reset, click Restart Now to restart the Wireless M2M Gateway. Also, you can set a Scheduling time to make the M2M Gateway restart ORing Industrial Networking Corp.
  • Page 41: Firmware Upgrade

    This page allows you to save configurations or return settings to previous status. You can download the configuration file from the Web. Note: users using old versions of Internet Explorer may have to click on the warning on top of the browser and choose Download File. ORing Industrial Networking Corp.
  • Page 42: Remote Management

    Restore Default Settings. The M2M Gateway will reboot to validate the default settings. Remote Management Set the Remote Management to access the M2M Gateway web pages from WAN side. Label Description Remote Management Enables or disables remote management function ORing Industrial Networking Corp.
  • Page 43: Miscellaneous (Ping)

    WAN, LAN settings. System Log The M2M Gateway keeps a running log of events and activities occurring on the M2M Gateway, several filters are provided for displaying related log entries. Click the button 'Refresh' to refresh the page. ORing Industrial Networking Corp.
  • Page 44: Traffic Statistics

    The IMG basic information and some serial port related function can be configure by using DS-tool, including the VCOM Mapping. 5.3.1 General settings This page display some basic information of the device and also includes the setting of device name. ORing Industrial Networking Corp.
  • Page 45: Security

    Label Description Device Name/location Input the name of the device. 5.3.2 Security Label Description New Password Enter a new login password. Confirm Retype the new password to confirm it. Password Current Password Type in current password ORing Industrial Networking Corp.
  • Page 46: Network Setting

    All devices on the network must have the same subnet mask to Network communicate with each other on the network. 5.3.4 Upgrade Firmware Label Description Firmware Browse to the location where the firmware image file is located and click Image update. 5.3.5 Reboot Device ORing Industrial Networking Corp.
  • Page 47: Serial Settings

    Latency: This mode optimized for shortest response time. Delimiter: Serial You can define max. 4 delimiters (00~FF, Hex) for each way. The data will Ethernet be hold until the delimiters are received or the option “Flush Serial to ORing Industrial Networking Corp.
  • Page 48: Service Mode

    Port of the serial server serial port to local COM port on the host computer. Virtual COM Mode also supports up to 5 simultaneous connections, so that multiple hosts can send or receive data by the same serial device at the same time. ORing Industrial Networking Corp.
  • Page 49 (Alive Check) to remote host to check the Alive Check TCP connection. If the TCP connection is not alive, the connection will be closed and the port will be freed. 0 indicate disable this function. Factory default is 0. ORing Industrial Networking Corp.
  • Page 50: Tcp Server Mode

    5 simultaneous connections, so that multiple device can receive data from the same serial device at the same time. Label Description Encryption with Use SSL to encrypt data Data Port Set the port number for data transmission. ORing Industrial Networking Corp.
  • Page 51: Tcp Client Mode

    In TCP Client Mode, device can establish a TCP connection with server by the method you have settled (Startup or any character). After the data has been transferred, device can disconnect automatically from the server by using the TCP alive check time or Idle time settings. ORing Industrial Networking Corp.
  • Page 52 If the TCP connection is not alive, the connection will be closed and the port will be freed. 0 indicate disable this function. Factory default is 0. Connect on Startup The TCP Client will build TCP connections once the connected ORing Industrial Networking Corp.
  • Page 53: Udp Mode

    Compared to TCP communications, UDP is faster and more efficient. In UDP mode, you can Uni-cast or Multi-cast data from the serial device server to host computers, and the serial device can also receive data from one or multiple host ORing Industrial Networking Corp.
  • Page 54: Technical Specifications

    41 (W) x 70 (D) x 95 (H) mm (1.61 x 2.76 x 3.74 inch) Weight (g) 360 g Environmental Storage Temperature -40 to 85 C (-40 to 185 Operating Temperature -10 to 60 C (14 to 140 ORing Industrial Networking Corp.
  • Page 55 5% to 95% Non-condensing Regulatory Approvals FCC Part 15, CISPR (EN55022) class A EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 Shock IEC60068-2-27 Free Fall IEC60068-2-32 Vibration IEC60068-2-6 Safety EN60950-1 Warranty 3 years ORing Industrial Networking Corp.