Please refer to the Technical Specifications section for more details. WARRANTY ORing warrants that all ORing products are free from defects in material and workmanship for a specified warranty period from the invoice date (5 years for most products). ORing will repair or replace products found by ORing to be defective within this warranty period, with shipment expenses apportioned by ORing and the distributor.
Operating temperature: -25 to 70°C Storage temperature: -40 to 85°C Operating humidity: 5% to 95%, non-condensing Dimensions: 250 (W) x 220 (D) x 87 (H) mm (9.84 x 8.66 x 3.4 inch) ORing Industrial Networking Corp.
4. Serial port 2 status LED 5. WAN status LED 10. 3G/4G antenna connector 2.1.2 Front Panel LEDs Color Status Description Green Power is supplied over Ethernet Serial 1/2 Green Blinking Transmitting data Green Port is linked ORing Industrial Networking Corp.
WLAN is activated WLAN Green Blinking Transmitting data Green Modem is connected 2.2 Top Panel On the top panel sits a SIM card slot and a cellular antenna connector, as show as below. 1. Wi-Fi antenna connector ORing Industrial Networking Corp.
The device can be fixed to a pole or the wall using the supplied mounting plate. Make sure the connectors on the bottom panel are facing down when installing to prevent water intrusion. Mounting plate ORing Industrial Networking Corp.
Follow the steps below to install the device to the wall. Step 1: Attach the mounting plate to the back of the device using four screws. The plate can be attached vertically or horizontally to the device based on the space available. ORing Industrial Networking Corp.
Page 10
Step 2: Hold the device upright against the wall Step 3: Insert four screws through the large opening of the keyhole-shaped apertures at the top and bottom of the plate and fasten the screw to the wall with a screwdriver. ORing Industrial Networking Corp.
When installing the device to a pole: Step 1: Attach the mounting plate to the back of the device using four screws. The plate can be attached vertically or horizontally to the device based on the space available. ORing Industrial Networking Corp.
Page 12
IMG-W6121GT+-M12 User Manual Step 2: Thread the two supplied metal mounting straps through the large slots on the mounting plate and then put the straps around the pole. ORing Industrial Networking Corp.
The device provides two N-type female connectors for Wi-Fi antennas. You can also use external RF cables and antennas with the connectors. 4.4 Cellular Antenna The device provides one cellular connector for 3G and 4G antennas. External RF cables and antennas can also be used with the connector. ORing Industrial Networking Corp.
A login window will pop up where you can enter the default login name admin and password admin. For security reasons, we strongly recommend you to change the password. Click on System Tools > Login Setting after logging in to change the password. ORing Industrial Networking Corp.
Shows the elapsed time since the Gateway is started Wan IP Shows WAN IP address 5.2.1 Basic Setting This section will guide you through the general settings for the gateway. This page allows you to configure WAN settings. Different WAN connection types will have ORing Industrial Networking Corp.
Page 17
Type a link in the field to test your Internet connection Enter a PIN code if you want to perform PIN check Auto Connect Check to start connections when the gateway boots up Reconnect on Failure Check to allow for reconnection when links fail ORing Industrial Networking Corp.
Page 18
Shows the status of SIM card Operations Click Connect to start modem/3G connections or Disconnect to shut down connections Link Status Shows the status of connections Modem Status Shows information about the modem WAN Connection Type as Wireless Client ORing Industrial Networking Corp.
Site to use it to check if the connection is alive or lost. This page allows you to configure the IP settings of the LAN for the gateway. The LAN IP address is private to your internal network and is not visible to Internet. ORing Industrial Networking Corp.
MAC address requesting an IP address from the gateway, it will be assigned with the IP address according to the mapping. You can choose one from the client list and add it to the mapping list. ORing Industrial Networking Corp.
Page 21
48 hours. Local Domain Name Enter the local domain name of a private network (optional). The DHCP will assign the entered domain to DHCP clients. DNS Server 1&2 Enter the IP address for the DNS server (optional) ORing Industrial Networking Corp.
You can set the device to work in AP mode. This is the most common mode for all wireless APs. In this mode, the AP will act as a central connection point which other wireless clients can connect to. ORing Industrial Networking Corp.
Page 23
This function is useful SSID) when many wireless clients request your network frequently. You can choose the security type for your WLAN connection from Security options the following options: None: no encryption ORing Industrial Networking Corp.
Page 24
(American Standard Code for Information Interchange) is a code for representing English characters as numbers in the Key Type range from 0 to 127. Hex digits uses 0–9 to represent values zero to nine, and characters A-F to represent values ten to fifteen. ORing Industrial Networking Corp.
Page 25
Enter a pass phrase in this field. The value must be within 8 to Shared Key 64 characters When you set security type as WPA /WPA2 Enterprise, the following screen will appear to allow you to configure individual settings. Label Description Auth Mode Available values include WPAPSK, WPA2PSK, ORing Industrial Networking Corp.
Page 26
A-F to represent values ten to fifteen. Default Key Index Select one of the keys to be the active key Key 1 to 4 Input up to four encryption keys Radius Server IP Enter the IP address of the RADIUS server ORing Industrial Networking Corp.
Remote Management Enables or disables remote management function Enable to allow using of serial data port and control port through Port External Access WAN access. Serial Configuration This page allows you to configure serial port parameters. ORing Industrial Networking Corp.
Page 28
(4K Bytes), the queued data will be sent. 0 means disable. Factory default value is 0. Throughput: This mode is optimized for the highest transmission Performance speed. Latency: This mode is optimized for the shortest response time. ORing Industrial Networking Corp.
COM port on the host computer. The Virtual COM mode also supports up to 5 simultaneous connections, so that multiple hosts can send or receive data by the same serial device at the same time. ORing Industrial Networking Corp.
The TCP Server mode also supports up to 5 simultaneous connections, so that multiple device can receive data from the same serial device at the same time. ORing Industrial Networking Corp.
In TCP Client mode, the device can establish a TCP connection with a server by the method you set (Startup or any character). After the data has been transferred, device can disconnect automatically from the server by using the TCP alive check time or Idle timeout settings. ORing Industrial Networking Corp.
UDP Client Mode Compared to TCP communications, UDP is faster and more efficient. In UDP mode, you can Uni-cast or Multi-cast data from the serial device server to host computers, and the ORing Industrial Networking Corp.
Choose a DDNS service provider from the list User Name Enter the user name of your DDNS account Password Enter the password of your DDNS account Domain Enter the domain name provided by your dynamic DNS service provider ORing Industrial Networking Corp.
Time from Browser 5.2.2 Networking Setting This section will guide you through various networking settings, including wireless, NAT, firewall, VPN, VRRP, and routing protocol. Wireless Setting Advanced This page allows you to set up wireless configuration. ORing Industrial Networking Corp.
Page 35
When the AP sends a DTIM with a DTIM interval value, the client hearing the beacons will awake to receive the messages. The default value is 1, and the value must be between 1 and 255 ORing Industrial Networking Corp.
Page 36
When wireless clients survey the local area for wireless networks to associate with, they will detect the SSID broadcasted by the AP. Click Enable if you want to broadcast the AP SSID, otherwise click Disable to inactivate the function. ORing Industrial Networking Corp.
Select one of the options to allow or deny the MAC address in the list Associated Clients Shows the wireless MAC addresses associated with the gateway MAC Filter Table You can edit up to MAC addresses in these fields ORing Industrial Networking Corp.
The port number of the service used by the private IP computer Enable Now Enables the virtual server entry after adding it Virtual server list Click Edit to edit the virtual service entry and Del to delete the entry. ORing Industrial Networking Corp.
NAT-PMP allows a computer in a private network (behind a NAT router) to automatically configure the gateway to allow parties outside the private network to contact with each other. NAT-PMP operates with UDP. It essentially automates the process of port ORing Industrial Networking Corp.
Enables or disables the IP Filter Description Enter description for the entry. Rule Configures the rules to be applied to the IP filter. Available options include DROP, ACCEPT, and REJECT. Direction Specifies the direction of data flow to be filtered ORing Industrial Networking Corp.
SSID. Firewall rules are evaluated from top to bottom. The first rule that matches is applied, and subsequent rules are not evaluated. If no rules match, the default rule (allow all traffic) is applied. ORing Industrial Networking Corp.
VPNs, WiFi security, and enterprise-level remote access with load balancing, failover, and fine-grained access control features. To set up your gateway as an Open VPN server, you need to install openvpn client software your Windows-based download from http://openvpn.net/download.html#stablel. ORing Industrial Networking Corp.
Page 43
Connection to Open VPN Server When you enable Open VPN Client, you need two gateways to create site-to-site VPN connections. The server IP and client IP address should be within the same network domain. Open VPN Server and Client Connection ORing Industrial Networking Corp.
Page 44
Otherwise, VPN clients can Options access the shared resources of only those computers directly connected to the local network of the device. LZO Compression Enables or disables the LZO Compression. Check the box will enable compression over VPN. ORing Industrial Networking Corp.
For more information, please visit openvpn website. Routing Setting Label Description Common Name Enter a common name for you to identify the VPN Subnet IP Address Enter the subnet IP address for the VPN. ORing Industrial Networking Corp.
Connect to my work space (VPN) > Use VPN to Internet, and then enter the user name and password set in the page. After setting up a new connection, you can make configurations in the following page. ORing Industrial Networking Corp.
Enter the username and password pairs in the form of user * pass *. Multiple username and password pairs are allowed. PPTP Client If a gateway wants to link to the gateways in different networks, you should enable PPTP client in the following page. ORing Industrial Networking Corp.
Page 48
IMG-W6121GT+-M12 User Manual ORing Industrial Networking Corp.
Using a virtual router ID (VRID) address and virtual router IP (VRIP) address to represent itself, a virtual router consists of two or more physical routers, including one master router and one or more backup routers. All routers in the virtual router group ORing Industrial Networking Corp.
Page 50
IMG-W6121GT+-M12 User Manual share the same VRID and VRIP. The master router provides primary routing and the backup routers monitor the status of the master router and become active if the master router fails. ORing Industrial Networking Corp.
When RIPv1 & v2 is Disabled, the gateway will operate in static routing mode, which means gateways forward packets using either route information from route table entries that you manually configure or the route information that is calculated using dynamic routing algorithms. ORing Industrial Networking Corp.
Page 52
BGP; however, the device only supports RIP (Routing Information Protocol). Do not choose Disable in the RIPv1 & v2 list if you want to enable Dynamic Routing. After clicking Apply, more information will be displayed in Current Routing Table. ORing Industrial Networking Corp.
Choose Disable to disable dynamic routing or other options to configure the interfaces for dynamic routing Telnet Setting This option is only available when dynamic routing is enabled. It allows you to make detailed configurations via simple comments. Routing Topography ORing Industrial Networking Corp.
Enable Now Check to activate the function immediately or at a later time. 5.2.3 System Tools Login Setting You can change login name and password in page. The default login name and password are both admin. ORing Industrial Networking Corp.
Description Restart Now Click to restart the gateway via warm reset Scheduling Enable: check to activate the setting Restart at: specify the time for resetting the gateway. You can configure the action to be performed periodically. ORing Industrial Networking Corp.
ORing launches new firmware constantly to enhance gateway performance and functions. To upgrade firmware, download new firmware from ORing’s website to your PC and install it via Web upgrade. Make sure the firmware file matches the model of your gateway. It will take several minutes to upload and update the firmware.
This page enables you to run ping test which will send out ping packets to test if a computer is on the Internet or if the WAN connection is OK. Enter a domain name or IP address in the destination box and click Ping to test. ORing Industrial Networking Corp.
When an error occurs, the gateway will notify you through system log, e-mail, SNMP, and relay. System Log Label Description Syslog Server IP Enter the IP address of a remote server if you want the logs to be stored remotely. Leave it blank will disable remote syslog. ORing Industrial Networking Corp.
Specifies the port to be logged remotely. Default port is 514. E-mail Label Description SMTP Server Enter a backup host to be used when the primary host is unavailable. Server Port Specifies the port where MTA can be contacted via SMTP server ORing Industrial Networking Corp.
Page 60
IMG-W6121GT+-M12 User Manual E-mail Address 1-4 Enter the mail address that will receive notifications SNMP Label Description SNMP Agent SNMP (Simple Network Management Protocol) Agent is a ORing Industrial Networking Corp.
You can configure the device to send notifications via SMS when the selected event occurs. You need to provide the phone number with which you want to receive the notifications and the time intervals between delivery attempts. ORing Industrial Networking Corp.
IMG-W6121GT+-M12 User Manual 5.2.4 System Status System Info This page displays the detailed information of the gateway including model name, description, firmware version, WAN, LAN and wireless settings. ORing Industrial Networking Corp.
You can click Refresh to renew the page or Clear Logs to clear all or certain log entries. Traffic Statistics This page displays network traffic statistics for packets both received and transmitted through Ethernet ports and wireless connections. ORing Industrial Networking Corp.
IMG-W6121GT+-M12 User Manual Wireless Link List This page displays the Mac address of all wireless clients connected. ORing Industrial Networking Corp.
“Digital Apparatus,” ICES-003 of Industry Canada. Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils numériques de Classe B prescrites dans la norme sur le matérial brouilleur: “Appareils Numériques,” NMB-003 édictée par l’Industrie. ORing Industrial Networking Corp.
Page 68
Avertissement d'exposition RF: L'équipement est conforme aux limites d'exposition aux RF établies pour un incontrôlés environnement. L'antenne (s) utilisée pour ce transmetteur ne doit pas être co-localisés ou fonctionner en conjonction avec toute autre antenne ou transmetteur. ORing Industrial Networking Corp.
Need help?
Do you have a question about the IMG-W6121+-4G-M12 and is the answer not in the manual?
Questions and answers