Page 1
Compact Air Handling Unit Installation instructions V1 (1/2)
Page 2
All rights reserved E&OE Operation and Maintenance Instructions Systemair AB reserves the rights to alter their products without notice. This also applies to products already ordered, as long as it does not affect the previously agreed specifications. Operation and Maintenance Instructions...
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. 2 Product information 2.1 General This installation manual concerns air handling unit type Topvex FC manufactured by Systemair Sverige AB. The units include the following model options: • Model: VSC 700, VSC 1500, VSC 2000 •...
Topvex FC 2.2.1 Dimensions and weight Compact Air Handling Unit 1400 1330 Model Weight, kg VSC 700 VSC 700 EL VSC 700 HW Operation and Maintenance Instructions Operation and Maintenance Instructions 125918-EN_GB Systemair AB Document in original language 2015-03-16 A001...
Page 6
1700 Topvex FC Compact Air Handling Unit 1630 Model Weight, kg VSC 1500 VSC 1500 EL VSC 1500 HW Operation and Maintenance Instructions Operation and Maintenance Instructions 125918-EN_GB Systemair AB Document in original language 2015-03-16 A001...
Page 7
2000 Topvex FC Compact Air Handling Unit 1630 Model Weight, kg VSC 2000 VSC 2000 EL VSC 2000 HW Operation and Maintenance Instructions Operation and Maintenance Instructions 125918-EN_GB Systemair AB Document in original language 2015-03-16 A001...
2.2.2 Space required Topvex FC Compact Air Handling Unit Model W (mm) VSC 700 VSC 1500 VSC 2000 Operation and Maintenance Instructions Operation and Maintenance Instructions 125918-EN_GB Systemair AB Document in original language 2015-03-16 A001...
At delivery the unit is fastened to the pallet with 4pcs screws. Unscrew the srews from the pallet. When transporting the VSC units use a forklift. Operation and Maintenance Instructions Fig. 1 Operation and Maintenance Instructions 125918-EN_GB Systemair AB Document in original language 2015-03-16 A001...
3.1 Unpacking Verify that all ordered equipment are delivered before starting the installation. Any deviation from the ordered equip- ment must be reported to the supplier of Systemair products. 3.2 Where/how to install VSC are meant for indoor installation. The electronic components should not be exposed to lower temperature than 0°...
Fig. 4 - Drainage connection Operation and Maintenance Instructions Table 1 H (mm) Max. Negative pressure (Pa) 1000 NOTE: It is recommended to use a ball trap siphon Operation and Maintenance Instructions 125918-EN_GB Systemair AB Document in original language 2015-03-16 A001...
The units are designed for ceiling installation Topvex FC Compact Air Handling Unit Fig. 5 Table 2 Symbol description Symbol Description Supply air Exhaust air Outdoor air Extract air Operation and Maintenance Instructions Operation and Maintenance Instructions 125918-EN_GB Systemair AB Document in original language 2015-03-16 A001...
Connect the unit electrically to the mains power supply through the all pole circuit breaker (safety switch). Led the wiring directly to the electrical connection box. Be careful not to cut the wiring. Operation and Maintenance Instructions Operation and Maintenance Instructions 125918-EN_GB Systemair AB Document in original language 2015-03-16 A001...
Fan extract air Filter supply air Filter extract air Operation and Maintenance Instructions Heat exchanger Electrical connection box Damper by-pass outdoor air Re-heater battery with manual everheat protection Operation and Maintenance Instructions 125918-EN_GB Systemair AB Document in original language 2015-03-16 A001...
See the enclosed wiring diagram for internal and external wiring. All external connections to possible accessories are made to terminals inside the electrical connection box (chapter 3.5.5). Operation and Maintenance Instructions Operation and Maintenance Instructions 125918-EN_GB Systemair AB Document in original language 2015-03-16 A001...
Page 16
SSR relay - EL heater Operation and Maintenance Instructions Terminals for mains supply to the unit and air dumpers control Main switch Safety contactor Terminals for external components Fans fuses Operation and Maintenance Instructions 125918-EN_GB Systemair AB Document in original language 2015-03-16 A001...
Fire contact NC contact 73 - DI3 Occupancy contact NC contact * Avalible only for VSC 700 HW, VSC 1500 HW, VSC 2000 HW Operation and Maintenance Instructions Operation and Maintenance Instructions 125918-EN_GB Systemair AB Document in original language 2015-03-16 A001...
• RS485(BACnet): 50-51-52 • RS485(Exoline): 50-51-52-53 • TCP/IP Exoline Compact Air Handling Unit • TCP/IP Modbus • TCP/IP WEB • TCP/IP BACnet RS 485 connection: Operation and Maintenance Instructions Operation and Maintenance Instructions 125918-EN_GB Systemair AB Document in original language 2015-03-16 A001...
Page 19
Systemair AB reserves the right to make changes and improvements to the contents of this manual without prior notice. Systemair AB Unit 28, Gravelly Industrial Park, Birmingham, B24 8HZ Tel: +44 (0) 121 322 0200 Fax: +44 (0) 121 322 0201...