Page 1
Installation Instructions Dispensing Towers Draft Arm, Lucky, Panther or Tee Towers Draft Arm Lucky Tower Panther Tower Tee Tower Form No. Z2351 Rev. 04.17.19 PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
Attaching the Gas Line Tubing ..............................18 Attaching the Tapping Hole Covers ............................18 Attaching the Air Distributor Cover ............................19 Checking the System for Leaks ..............................19 Appendix ....................................... 20 PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
DRAFT ARMS, 2-6 FAUCET TEE TOWERS, LUCKY AND PANTHER TOWERS Please follow these instructions to ensure proper installation of Perlick beer and wine dispensing towers. These instructions cover 3” Draft Arms and Tee, Lucky and Panther Towers. These instructions apply to the following beer and...
Page 4
- Air Distributor Cover 68678-1 - DZS36 Air Distributor Cover 68779-1 - Gas/CO2 Tubing C23975-1 - Beer Line Connector 532 - Wine Line Connector 67750 - Anti-Microbial Drain Tubing 1390D PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
Air Scoops for Field Retrofit Kits (-R) only - see page 9. - Air Scoop 69315-1 For BBR/BBRN/PTR - Air Scoop 68686-2 For DZS60 - Air Scoop 68778-1 For PTS - Air Scoop 68685-1 For BBS/BBSN PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
304 stainless steel probe, as well as flavor-lock tubing, all to protect the delicate flavors of wines. To preserve the integrity of Perlick WINEcertified wine products and systems, DO NOT use beer kit components in wine systems.
1. Place the air distributor cover bracket behind the air distributor assembly and mount it to the desired location on the cabinet wall. (Two-line assembly shown.) PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
1. A PVC tube, (Part #67562), is included in the tapping kit. This will be used as an air shaft when mounting to a counter top. Please refer to Diagram 7 in the Appendix for detail on how to mount a Draft Arm or Tee Tower to a counter top.
8. Apply a bead of silicone around the perimeter of the drainer. PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
2. Use the mountable cable tie and a self-drilling screw to hold the black air tube out of the way of keg loading and unloading. PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
Note: Keg couplers supplied with the wine tapping kit have 300 series stainless steel components to protect the delicate flavors of wine. 3. Repeat for each additional supply tube. PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
2. The system can be checked by doing a pressure decay test or by tapping the system and inspecting for product leaks and checking for gas leaks with soap and bubbles. Repair any leaks immediately. PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
1. Align splines on faucet to nut on faucet head. Orient faucet so it is perpendicular to the cabinet top. Hand tighten. 2. Using the spanner wrench provided, snug faucet tight. Do not over- tighten. PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
8. Apply a bead of silicone around the perimeter of the drainer. PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
3. Attach the other end of the 1-1/8” vinyl tube to the air-cooled fitting on the Lucky or Panther tower and tighten with a hose clamp. Refer to Diagram 6 in the Appendix. PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
3. Position the covers tightly around the tubing and mount to the bottom side of the cabinet top using a cordless drill with a 5/16” socket head bit and the self-drilling screws provided. Please refer to Diagram 7 in the Appendix. PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
2. The system can be checked by doing a pressure decay test or by tapping the system and inspecting for product leaks and checking for gas leaks with soap and bubbles. Repair any leaks immediately. PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
PRODUCT INSTALLATION INSTRUCTIONS Dispensing Towers DISPENSING TOWERS DRAFT ARMS, 2-6 FAUCET TEE TOWERS, LUCKY AND PANTHER TOWERS APPENDIX - DIAGRAM 1 Single Tap Beer System PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
Page 21
PRODUCT INSTALLATION INSTRUCTIONS Dispensing Towers DISPENSING TOWERS DRAFT ARMS, 2-6 FAUCET TEE TOWERS, LUCKY AND PANTHER TOWERS APPENDIX - DIAGRAM 2 Tapping in Series PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
Page 22
PRODUCT INSTALLATION INSTRUCTIONS Dispensing Towers DISPENSING TOWERS DRAFT ARMS, 2-6 FAUCET TEE TOWERS, LUCKY AND PANTHER TOWERS APPENDIX - DIAGRAM 3 Drip Pan Drain Connection and Tapping Hole Cover Installation PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
Page 23
DISPENSING TOWERS DRAFT ARMS, 2-6 FAUCET TEE TOWERS, LUCKY AND PANTHER TOWERS APPENDIX - DIAGRAM 4 Air Distributor Connections and Excess Drip Pan Drain Tube Mounting PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
Page 24
PRODUCT INSTALLATION INSTRUCTIONS Dispensing Towers DISPENSING TOWERS DRAFT ARMS, 2-6 FAUCET TEE TOWERS, LUCKY AND PANTHER TOWERS APPENDIX - DIAGRAM 5 Air Scoop Installation PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
Page 25
PRODUCT INSTALLATION INSTRUCTIONS Dispensing Towers DISPENSING TOWERS DRAFT ARMS, 2-6 FAUCET TEE TOWERS, LUCKY AND PANTHER TOWERS APPENDIX - DIAGRAM 6 Air Sleeve Installation through Countertop and Back Bar Cabinet PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
Page 26
PRODUCT INSTALLATION INSTRUCTIONS Dispensing Towers DISPENSING TOWERS DRAFT ARMS, 2-6 FAUCET TEE TOWERS, LUCKY AND PANTHER TOWERS APPENDIX - DIAGRAM 7 Air Connection PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com...
Page 27
2 1/4" AIR HOSE CONNECTION CLEARANCE HOLE 2 1/2" FOR FLANGED NUT Form No. Z2351 Rev. 04.17.19 4 1/4" 1 1/2" PERLICK CORPORATION 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • perlick.com ANCE AIR HOSE D NUT...
Need help?
Do you have a question about the Draft Arm and is the answer not in the manual?
Questions and answers