7.1.2
Lubrication
All gear units are filled in the works with synthetic gear oil (polyglycol) of viscosity class
ISO VG 220 or with a high performance grease.
Other lubricants and quantities of lubricant are required for other operational conditions
(see Chapter 3.2). In such cases, please contact SIEMENS
Service.
No lubricant change for these types of gear units!
The venting plug located under the adaptor plate must not be opened!
The fixing bolts of the adaptor plate must not be loosened. These bolts hold the
gear housing together.
7.2
Disposal
Motors must be disposed of in accordance with the national and local regulations by
putting them into the standard recycling process or by returning them to the
manufacturer.
The following points must be observed when disposing of the motors:
- Dispose of oil in accordance wit the old oil ordinance (for example no mixing with
solvents, cold cleansers or lacquer residues)
- Separate components for recycling into:
- electronic scrap (encoder electronics)
- scrap iron
- aluminium
- nonferrous metals (worm wheels, motor windings)
- permanent magnets
Danger of crushing injuries. People with heart pacemakers must keep well away
as they at risk from the effects of the permanent magnets!
8
Other applicable documentation
These operating instructions are valid in conjunction with the following documentation:
- Project planning guide1FK7/1FT6,
Ordering / Item number 6SN1197-0AD06-... / 6SN1197-0AD02-...
- Operating instructions for the three-phase servomotor 1FK7/1FT6,
Ordering / Item number 610.40 700.21 / 610.43 410.21
- Repair instructions for the three-phase servomotor 1FK7/1FT6,
Ordering / Item number 610.43 430.21 / 610.43 411.02