CHECK FOR GAS LEAKS!

After all connections are completed, check all connections and fittings for leaks with a soap solution.
.
With all valves closed, apply the leak check solution (50/50 mix of dish washing detergent and water)
to all gas carrying connections and fittings.
.
Open tank valve.
.
Presence of bubbles at areas of wet solution indicates a gas leak.
.
If Leaks are detected or you smell or hear gas, IMMEDIATELY shut off the valve and repair the
leak or replace the defective part. Do not use the Smoker until all leaks are corrected!

SET-UP TIPS

. When setting up the smoker and tank, it is recommended to have the tank and smoker on a line perpendicular to the wind
direction.
. The gas hose/regulator assembly should be totally extended to the maximum distance so that the hose is straight and the
tank is as far from the smoker as it can be.
. LP tanks are intended for operation in the upright position only.
. Care should be taken to protect the fuel supply hose from damage from either foot or vehicle traffic.
. If the appliance is not in use, the gas must be turned off at the supply cylinder and the cylinder should be disconnected
from the appliance.
. Storage of the Smoker indoors is only permissible if the cylinder is disconnected and removed from the Smoker.
WARNING!
Be sure to follow ALL SAFETY
WARNINGS and precautions
that are contained in this
instruction manual before
using this Smoker!
NEVER leave this appliance
unattended!
The Smoker becomes
EXTREMELY HOT!
When the Smoker is not in use,
the gas MUST BE TURNED
OFF at the supply cylinder.
14