Installing a LSP
Installing in multibay
Ê Open the server as described in the
seq..
Ê Disconnect all cables at the rear side of the multibay. Notice the cabling.
Ê Press inward on the two metal tongues of the EasyClick rails until the locking
mechanism disengages.
Ê Remove the multibay from the bay.
Figure 35: Removing the dummy cover
Ê Push the dummy cover from the inside out of the bay frontward.
V
CAUTION!
Keep the dummy cover in a safe place. If you remove the ServerView
Local Service Panel again and do not replace it with a new one, the
dummy cover must be reinstalled to comply with EMC regulations and to
satisfy cooling requirements and fire protection measures.
52
ServerView Local Service Panel
chapter "Preparation" on page 21
Options Guide