READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR OWN SAFETY
• DISCONNECT AC POWER SUPPLY BEFORE SERVICING.
• Installation and servicing of this equipment should be performed by qualified service personnel only.
• Ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.
• Do not mount near gas or electrical heaters.
• Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by
unauthorized personnel.
• The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. Any
modification or use of non-original components will void the warranty and product liability.
• Do not use this equipment for other than intended use.
The specialtyLED Ribbon Flex is an extremely small profile product made up of Light Emitting Diodes (LED)
mounted on a thin flexible copper strip. The wet version has a clear flexible silicon housing. Due to the construction of
the product, special care needs to be taken during the installation process in order to avoid damaging the LEDs or any
of the resistors.
SAFETY PRECAUTIONS:
• Do not over bend to the side, product is only bendable front to back.
• Do not cover the product unless done so with extreme caution and attention to ventilation.
• Do not apply power when tightly coiled. Maintain half inch spacing between parts.
• Do not puncture, cut, shorten or splice outside of the designated cutting marks.
• Do not route through walls, doors, windows or building structures.
• Do not mount inside cabinets, tanks or enclosures unless properly ventilated.
• Do not unroll on a rough surface or over sharp corners. This will scratch or damage the LEDs.
• When unrolling or installing do not twist, pull or kink the product.
• Do not secure with staples, nails or like means that can damage the insulated PVC housing.
• Do not install in locations where it is subject to continuous flexing.
• Do not submerge in liquid or apply near standing water.
• Do not operate in temperatures exceeding 149°F (65°C).
• Ground Fault Circuit Interrupter (GFCI) protection should be provided on all circuits when used for outside
applications.
• Do not operate on circuits that do not have proper surge suppression protection. High voltage spikes will
damage the LEDs.
• Do not operate over specified voltage, LED life degradation will be greatly increased.
40070009 REV 1 11/2014
SAVE THESE INSTRUCTIONS!
INSTALLATION INSTRUCTIONS
1
INSTALLATION INSTRUCTIONS
800.533.3948 • www.barronltg.com
RFX

Advertisement

loading

Summary of Contents for BARRON specialityLED RFX

  • Page 1 INSTALLATION INSTRUCTIONS SAVE THESE INSTRUCTIONS! READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR OWN SAFETY • DISCONNECT AC POWER SUPPLY BEFORE SERVICING. • Installation and servicing of this equipment should be performed by qualified service personnel only. • Ensure the electricity connections conform to the National Electrical Code and local regulations if applicable. •...
  • Page 2 INSTALLATION INSTRUCTIONS General Material/Tool Requirements: Material needed for installation: Additional wire as needed for connections RFX Ribbon Flex Reel (16.4’) Measuring tape RFX Transformer Scissors RFX accessories (Optional) 1. Measure the installation location to determine product length. Due to circuitry, RFX has a 2” cutting increment. 2.
  • Page 3 INSTALLATION INSTRUCTIONS ACCESSIORIES Fig. 2 • RFX-CSS-XXX is designed to join (2) cut sections together. (Fig. 2) • RFX-CSS-FLEX-XXX is designed to join (2) cut sections together with 2” wire spacing allowing the RFX to bend or turn corners. (Fig. 3) •...

This manual is also suitable for:

Specialityled rfx-wet