READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
When using electrical equipment, basic safety precautions should always be followed including the following:
• DISCONNECT AC POWER SUPPLY BEFORE SERVICING.
• Installation and servicing of this equipment should be performed by qualified service personnel only.
• Ensure that the electrical wiring conforms to the National Electrical Code NEC® and local regulations
if applicable.
• Do not mount near gas or electrical heaters.
• Do not use outdoors.
• Equipment should be mounted in locations and at heights where it will not be readily subjected to tampering
by unauthorized personnel.
• The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
• Any modification or use of non-original components will void the warranty and product liability.
• Do not use this equipment for other than intended use.
• Allow battery to charge for 24 hours before first use.
• For use with metal enclosed wiring systems.
10070218 REV 3 - 09/19
IMPORTANT SAFEGUARDS
SAVE THESE INSTRUCTIONS!
Technical Support
■ (623) 580-8943 ■ technicalsupport@barronltg.com
1
800-533-3948 www.barronltg.com

Advertisement

loading

Summary of Contents for BARRON Exitronix S900C Series

  • Page 1 S900C Series Installation Instructions IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. When using electrical equipment, basic safety precautions should always be followed including the following: • DISCONNECT AC POWER SUPPLY BEFORE SERVICING. • Installation and servicing of this equipment should be performed by qualified service personnel only. •...
  • Page 2 S900C Series Installation Instructions Recessed Ceiling or Recessed Wall Mount Joists Bar Hanger Recessed Housing 1. Position the recessed kit between the joists (Fig. 1). NOTE: If using a single face EXIT sign, make sure to position the recessed kit such that when the EXIT panel assembly is installed, it will be in the correct orientation.
  • Page 3 S900C Series Installation Instructions Surface Ceiling or Surface Wall Mount J-box Adjustable Crossbar 1. Attach the adjustable crossbar to the J-box using the (2) 8-32 x 1” End Cap screws (supplied). Use the slotted portion of the adjustable crossbar Canopy Enclosure Top Mount to mount to the J-box and position such that the portion with the...
  • Page 4: Electrical Connections

    S900C Series Installation Instructions Electrical Connections Make electrical connections as follows: 120VAC 277VAC White - Common White - Common Black - 120VAC Orange - 277VAC Note: Cap unused wires to prevent shorting. 1st Battery 2nd Battery LED Strip BATT 1 BATT 2 Orange - 277VAC INPUT...
  • Page 5: Operation

    S900C Series Installation Instructions Self-Test/Self-Diagnostics (G2) Operation The purpose of this option is to provide Self-testing and Self-diagnostic capabilities to the EXIT sign. At predetermined intervals, the EXIT sign will automatically switch into battery mode. Refer to the Self-Test Features section of this page for timing details.