Locator and fault probe
Ultra, Fault Finder on Ultra Advanced
• Fault mode is not available on basic locators.
• If locator does not have 263 Hz installed, fault finding will not work.
• Locator must be running firmware v6 or higher.
• The locator can also locate cables while in Fault Mode but performance will
vary based on the amount of current on the cable.
1. Press On/Off key to turn on locator.
2. Plug fault probe into accessory port.
3. When fault probe is plugged into locator, locator will enter fault mode.
Probe icon will show.
A home symbol flashes in the bottom right corner of the locate screen.
4. Connect transmitter to faulted cable following transmitter setup instructions.
Select power level 1 or 2 on transmitter and observe adequate current on the cable,
ideally at least 10 mA.