Connect With Live Power Adapte - Leica Ultra User Manual

Table of Contents

Advertisement

4.8
Setup
Danger
Ultra, How to Use the Transmitter

Connect with Live Power Adapte

1
1. Verify that transmitter is turned off.
2. Connect live power adapter to the transmitter.
3. Connect live power adapter black lead to the ground stake.
4. Connect live power adapter red lead to live power conductor.
5. Turn on transmitter.
6. Select frequency greater than 8 kHz. 29 kHz is preferred.
7. Adjust power level as needed.
8. Check battery level.
When finished locating the cable, turn off transmitter, disconnect live power adapter red
lead from live power conductor, disconnect live power adapter black lead from ground stake,
and disconnect live power adapter from transmitter.
Connecting live power adapter to a live service can result in an electric shock.
Precautions:
Do not operate equipment unless you are properly qualified to work on live power conduc-
tors.