10.5
Normal marker locating
mode
Ultra, Electronic Marker Location (EML) Accessory

Technique

1. Attach EML accessory to the locator.
2. Plug the EML cable into the locator accessory connector.
3. Select marker type using the frequency key.
Test unit for proper operation by passing the wand 1 m (3') over a marker.
Signal strength should increase and the bar graph should close.
4. Walk over area where you suspect a marker has been buried. Hold EML accessory close
to the ground and move it from side to side. Move in the direction of increasing signal
strength. Adjust gain as needed. Marker is located where locator indicates maximum
signal.
5. To locate next marker, adjust gain to 30 dB and repeat process.