Electrical Connections - FAAC 596MPS Manual

Hide thumbs Also See for 596MPS:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7
ENGLISH
These instructions apply to the following models:
Appliances 596MPS - 610MPS
1 . DESCRIPTION
The 596MPS electronic appliance is suitable for controlling up-
and-over automatic systems with single or double hydraulic
operator.
The 610MPS electronic appliance is suitable for controlling barriers
with a hydraulic operator.
1.1.
TECHNICAL SPECIFICATIONS
TABLE 1 OPERATING PARAMETERS OF 596MPS & 610MPS
(dip-switch selectable)
L o g i c
Pause time (sec.)
Work time (sec.)
Failsafe
TABLE 2 HARDWARE CHARACTERISTICS OF 596MPS & 610MPS
Power supply
Max absorbed power
Motors max. load
Power supply for accessories
Accessories max. load
Ambient temperature
F u s e s
Rapid connectors
Terminal boards
Terminal board inputs
Terminal board outputs
Courtesy timing
1.2.
LAY-OUT OF 569MPS & 610MPS CARD
J3
J3
F2
IC1
J4
F2
J4
J1
1
2
3
4
5
6
7
8
J1
596MPS & 610MPS
596MPS
610MPS
automatic (A) / semi-automatic (E)
30/60
0/2/5/10/15/30/60
25/30/35/40
4/5/7/9
enabled/disabled
230V~ (+6 -10 %) 50Hz
10 W
800 W
24Vdc
250 mA
- 20°C
+ 55°C
motor/accessories
for decoding-RP receiver cards
push-button for outside opening
removable
Open
Stop
Closure safety devices
Limit-switch
motor
capacitor
24 Vdc accessories power supply
courtesy light (596MPS)
flashlight (610MPS)
90 sec. (596MPS)
DS1
DS1
ON
1 2 3 4 5 6
TF1
RL1
RL3
RL2
J2
9
10
11
12
13
14
15
16

2. ELECTRICAL CONNECTIONS

ÜBefore attempting any work on the card (connections,
programming, maintenance), always turn off power.
Observe points 10, 11, 12, 13 and14 of the GENERAL SAFETY RULES.
Always separate 230V~ power cables from control and safety
cables (push-button receiver, photocells, etc.).
To prevent any electric noise whatever, use separate sheaths.
2.1.
J1
1
2
3
Altre sicurezze
Other safeties
Autres sécurités
Andere Sicherheiten
Otros disp. seg.
2.2.
(photocell with failsafe enabled)
J1
1
2
3
Fig. 1
Altre sicurezze
Other safeties
Autres sécurités
Andere Sicherheiten
Otros disp. seg.
TABLE 3COMPONENTS OF 596MPS & 510MPS CARD
F1
Fuse F1 5x20 5A/250V (motor/transformer primary winding)
F2
Fuse F2 5x20 0.5A/250V delayed (accessories power supply)
F1
DS1
Programming microswitches
F1
J1
Low voltage input/accessories terminal board
J2
Output terminal board for motor/capacitor/lamp
J9
J9
J3
Rapid connector for decoding/RP receiver cards
17
18
19
J4
Rapid connector for Open push-button
J9
230V power supply input terminal board
J2
6
596MPS CONNECTION LAY-OUT
(photocell with failsafe enabled)
596MPS
J2
4
5
6
7
8
9
10
11
C1
C2
5
RX
TX
4
2
3
1
2
1
610MPS CONNECTION LAY-OUT
610MPS
J2
4
5
6
8
9
7
10
11
C1
C2
5
RX
TX
4
2
3
1
2
1
ENGLISH
Fig. 2
J9
17
18
19
12
13
14
15
16
SERVICE LIGHT
230V~ 40W max
230V~
(+6% -10%)
50Hz
M1
M2
FAACLAMP
MINILAMP
Fig. 3
J9
17
18
19
12
13
15
14
16
FAACLAMP
230V~
MINILAMP
(+6% -10%)
50Hz
M1
M2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

610mps