Error Code [7102]

1. Error code definition
Wrong number of connected units
2. Error definition and error detection method
The number of connected indoor units is "0" or exceeds the allowable value.
3. Error source, cause, check method and remedy
Error source
Outdoor unit
(1)
Number of indoor units connected to the outdoor
terminal block (TB3) for indoor/ outdoor transmis-
sion lines exceeds limitations described below.
(2)
Disconnected transmission line of the outdoor unit 2)
(3)
Short-circuited transmission line
When (2) and (3) apply, the following display will
appear.
(4)
The model selection switch (SW5-7) on the out-
door unit is set to OFF. (Normally set to ON)
(5)
Outdoor unit address setting error
The outdoor units in the same refrigerant circuit do
not have sequential address numbers.
68
- chapter 7
Cause
Number of units
Restriction on the number of units
15 : 72 model
Total number of
indoor units
20 : 96 model
26 : 120 model
31 : 144 model
36 : 168 model
41 : 192 model
46 : 216 model
50 : 240 - 432 models
Total number of
LOSSNAY units
(During auto
0 or 1
address
start-up only)
1 : HP72 - 120 models
Total number of
outdoor units
2 : HP144 - 240 models
ME remote controller
Nothing appears on the remote controller be-
cause it is not powered.
MA remote controller
"HO" or "PLEASE WAIT" blinks.
Check method and remedy
1)
Check whether the number of units
connected to the outdoor terminal
block (TB3) for indoor/ outdoor
transmission lines does not exceed
the limitation. (See (1) and (2) on
the left.)
Check (2) - (3) on the left.
3)
Check whether the transmission
line for the terminal block for cen-
tralized control (TB7) is not con-
nected to the terminal block for the
indoor/outdoor transmission line
(TB3).
4)
Check the setting for the model se-
lection switch on the outdoor unit
(Dipswitches SW5-7 on the outdoor
unit control board).