Power Specifications; 1050 W Ac Power Supply - Cisco SE-CL-L3 Installation Manual

Application services engine hardware
Table of Contents

Advertisement

Power Specifications

Table 9: Environmental Specifications
Description
Temperature, Operating
Temperature, non-operating
(when the server is stored or transported)
Humidity (RH), operating
Humidity (RH), non-operating
(when the server is stored or transported)
Altitude, operating
Altitude, non-operating
(when the server is stored or transported)
Sound power level
Measure A-weighted per ISO7779 LwAd (Bels)
Operation at 73°F (23°C)
Sound pressure level
Measure A-weighted per ISO7779 LpAm (dBA)
Operation at 73°F (23°C)
Power Specifications
The power specifications for the supported power supply options are listed in the following section.

1050 W AC Power Supply

This section lists the specifications for each 1050 W AC power supply (Cisco part number
UCSC-PSU1-1050W).
Cisco Application Services Engine Hardware Installation Guide
86
Specification
50 to 95°F (10 to 35°C)
Extended environment 41 to 104°F (5 to 40°C)
Derate the maximum temperature by 1°C per every 305 meters of altitude above
sea level.
Although the ASHRAE guidelines define multiple classes with different
Note
operating ranges, the recommended temperature and humidity operating
range is the same for each class. The recommended temperature and
humidity ranges are:
• Operating Temperature: 64.4°F to 80.6°F (18°C to 27°C)
–40 to 149°F (–40 to 65°C)
8 to 90%
5 to 93%
0 to 10,000 feet
0 to 40,000 feet
5.5
40