Power Specifications - Cisco UCS C480 M5 Installation And Service Manual

Hide thumbs Also See for UCS C480 M5:
Table of Contents

Advertisement

Power Specifications

Table 9: Physical Specifications
Description
Temperature, Operating
Temperature, non-operating
(when the server is stored or transported)
Humidity (RH), operating
Humidity (RH), non-operating
(when the server is stored or transported)
Altitude, operating
Altitude, non-operating
(when the server is stored or transported)
Sound pressure level
Measure A-weighted per ISO7779 LpAm (dBA)
Sound power
Power Specifications
Note
Do not mix power supply types or wattages in the server. Both power supplies must be identical.
You can get more specific power information for your exact server configuration by using the Cisco UCS
Power Calculator:
http://ucspowercalc.cisco.com
The power specifications for the supported power supply options are listed in the following sections.
1600 W AC Power Supply
This section lists the specifications for each 1600 W AC power supply (Cisco part number
UCSC-PSU1-1600W).
Cisco UCS C480 M5 Server Installation and Service Guide
128
Specification
41 to 95°F (5 to 35°C)
Derate the maximum temperature by 1°C per every 305 meters of altitude above
sea level.
–40 to 149°F (–40 to 65°C)
10 to 90%
5 to 93%
0 to 10,000 feet (0 to 3048 m)
0 to 39,370 feet (0 to 12,000 m)
• Minimum configuration: 57.6 dBA
• Typical configuration: 63.5 dBA
• Maximum configuration: 70.5 dBA
• Minimum configuration: 7.08 bels
• Typical configuration: 7.67 bels
• Maximum configuration: 8.24 bels