Maintenance - Honeywell 1000 Series Installation Instructions Manual

Direct ignition gas control with integrated gas/air module
Table of Contents

Advertisement

VR9205R SERIES 1000 DIRECT IGNITION GAS CONTROL WITH INTEGRATED GAS/AIR MODULE
3. Watch for ignition spark or for glow at hot surface
igniter either immediately or following prepurge.
See DI module specifications.
4. Time the length of spark operation. See the DI mod-
ule specifications.
5. After the module locks out, enable the on/off switch
and make sure no gas is flowing to the main burner.
6. Set the thermostat below room temperature and
wait one minute.
7. Operate system through one complete cycle to
make sure all controls operate properly.

MAINTENANCE

Under normal circumstances no maintenance or service
is required.
WARNING
Fire or Explosion Hazard.
Can cause property damage, severe injury,
or death.
Do not disassemble the gas control; it contains no
replaceable components. Attempted disassembly,
repair, or cleaning can damage the control,
resulting in gas leakage.
SERVICE
WARNING
Fire or Explosion Hazard.
Can cause severe injury, death, or property
damage.
Do not disassemble the gas control; it contains no
replaceable components. Attempted disassembly,
repair, or cleaning can damage the control,
resulting in gas leakage.
CAUTION
Equipment Damage Hazard.
Can burn out thermostats or other
components in the control string.
Never apply a jumper across (or short) the valve
coil terminals, even temporarily.
IMPORTANT
These gas controls are shipped with protective
seals over the inlet and outlet tappings. Do not
remove the seals until ready to install adapters
or connect the piping.
After servicing, verify proper system operation.
If Main Burner Does Not
Come On With Call For Heat
1. Confirm the gas control switch is in the ON position.
2. Adjust thermostat several degrees above room
temperature.
3. Using an AC voltmeter, measure across the two ter-
minals on the gas valve.
4. If voltage is incorrect or not present, check control
circuit for proper operation.
5. If proper voltage is present, replace gas control.
INSTRUCTIONS TO THE
HOMEOWNER
WARNING
Fire or Explosion Hazard.
Can cause property damage, severe injury,
or death.
Follow these warnings exactly:
1. Before lighting, smell around the appliance for
gas. Be sure to smell next to the floor because
LP gas is heavier than air. If you smell gas:
a. Turn off the gas supply at the appliance
service valve. On LP gas systems, turn off
the gas supply at the gas tank.
b. Do not light any appliances in the house.
c. Do not touch electrical switches or use the
phone.
d. Leave the building and use a neighbor's
phone to call your gas supplier.
e. If you cannot reach your gas supplier, call the
fire department.
2. Replace the gas control in the event of any
physical damage, tampering, bent terminals,
missing or broken parts, stripped threads, or
evidence of exposure to heat.
IMPORTANT
Follow the operating instructions provided by the
heating appliance manufacturer. The information
below describes a typical control application, but
the specific controls used and the procedures
outlined in your appliance manufacturer
instructions can differ, requiring special
instructions.
To Turn ON Appliance
STOP! Read the Warnings
Above Before Proceeding.
1. The lighting sequence on this appliance is
automatic; do not attempt to manually light the main
burner.
2. If the furnace does not come on when the
thermostat is set several degrees above room
temperature, set the thermostat to its lowest setting
to reset the safety control.
3. Remove the burner access panel if provided on
your appliance.
4. Push the on-off switch to the OFF position.
5. Wait five minutes to allow any gas in the
combustion chamber to vent. Then if you smell gas,
STOP! Follow Step 1 in the Warning above. If you
do not smell gas, continue with the next step.
6. If you do not smell gas, push the electronic on-off
switch to the ON position.
7. Replace the burner access panel.
8. Reset the thermostat to the desired temperature.
9. If the appliance does not turn on, slide the switch to
OFF and contact a qualified service technician for
assistance.
7
69-2305—03

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vr9205r