DO000129_powersoft_IpalMod_uguide_en Data are subject to change without notice. For latest update please refer to the online version available on www.powersoft-audio.com.
7 : 3.Disposal of the packing material 11 : 4.6. CN2 pinout 7 : 4.Differential Pressure Control 11 : 5.IpalMod without DPC interface board 7 : 4.1. Virtual Transducer mode 11 : 6.Installing an optional DSP SIMM board 7 : 4.2. Pressure mode 12.
Page 4
15 : 8.1. Auxiliary power protections 17. Support and warranty 17 : 1.Service 17 : 2.Warranty 17 : 2.1. Return of Goods 17 : 2.2. Repair or replacement 17 : 2.3. Cost and responsibility of transport 17 : 3.Assistance ii | IpalMod | User guide...
8. Do not defeat the safety purpose of the polarized or grounding- Symbol for earth/ground connection. type plug. 9. Only use attachments/accessories specified by Powersoft. Symbol for conformity with Directive 2002/96/EC 10. Refer all servicing to qualified service personnel. Servicing is...
6. Assurez-vous d’une bonne ventilation de l’appareil. Installez en pour lors opérations de maintenance. accord avec les instructions préconisées par Powersoft. 7. N’installez pas l’appareil à proximité de sources de chaleur ou Le marquage CE indique la conformité à la directive de d’autres appareils produisant de la chaleur.
6. No bloquee las aberturas de ventilación. Realice la instalación de de operación o mantenimiento. acuerdo con las indicaciones de Powersoft. 7. No instale cerca ninguna fuente de calor como, por ejemplo, La marca CE indica el cumplimiento de la directiva radiadores, rejillas de calefacción, hornos u otros aparatos que...
DELL’UNITÀ. NON CI SONO PARTI INTERNE AD USO DELL’UTENTE. RIVOLGERSI A PERSONALE QUALIFICATO PER L’ASSISTENZA. NON ESPORRE QUESTO APPARECCHIO ALLA PIOGGIA, UMIDITÀ O SOSTANZE LIQUIDE. OGGETTI PIENI DI LIQUIDI, COME VASI, NON DEVONO ESSERE COLLOCATI SU QUESTO APPARATO. vi | IpalMod | User guide...
The Waste Electrical and Electronic Equipment Directive (WEEE Directive) aims to minimise the impact of electrical and electronic goods on the en- Luca Lastrucci vironment. Powersoft S.p.A. comply with the Directive 2002/96/EC and Managing Director 2003/108/EC of the European Parliament on waste electrical finance the cost of treatment and recovery of electronic equipment (WEEE) in order to reduce the amount of WEEE that is being disposed of in land-fill site.
It is recommended that all workstations where Electrostatic Discharge Sensitive devices (ESDS) and assemblies are handled outside of full static protection packaging (i.e. within static control areas) should be pro- vided with some form of ground conductive or dissipative flooring. viii | IpalMod | User guide...
The Differential Pressure Control – DPC – is the core IpalMod module. technology of the Integrated Powered Adaptive Loudspeaker We know you are eager to use the IpalMod module, but system, also known as IPAL. please take a moment to read this user’s manual and safety DPC makes IPAL systems efficient and reactive ®...
3400 W peak power, the dissipated heat is: as the peak power delivered by the module 3400 (1 - 0.8) as the highest ambient temperature = 170 W as the highest operating temperature 2 | IpalMod | User guide...
45 °C. 75 - 45 = 0.14°C/W 8 : 2.Suggested heatsink Powersoft provides an IpalMod compatible aluminium alloy (for further information, please refer to the DigiMod IK user heatsink, specifically designed to house the amp module, guide, available on Powersoft website).
In order to improve the electromagnetic compatibility prone to high an EMC filter must be inserted before the AC MAINS RF noise plugs on the power supply. Powersoft suggests the Schaffner FN2030-10-06 model. Parallel pair Configuration prone to RF noise...
Micro Match Socket 18 pin CN102 Interface board 2 Micro Match Socket Caution: do not connect any cable to the reserved CN1 connector on the IpalMod connection board: module doing so can result in permanent module damage. CN109 CN101 CN102 FIGURE 10: DPC interface to control board connections.
11 : 4.3. CN14 pinout 11 : 4.6. CN2 pinout Pin# Name Description Pin# Name Description reference ground 1-2-3-4 5-6-7-8 rail bus OUT 9-10 MUTE Mute command 11-12-13 not connected Aux –12 –12 V 14-15-16 Aux +12 +12 V 17-18-19 –V –V rail bus OUT...
Page 20
Neutral Earth Phase Remove jumper to activate external volume potentiometer COLD External volume potentiometer (optional) Single transducer mode Dual transducers mode FIGURE 13: IpalMod: mains and audio connections. 10 | IpalMod | User guide...
The IpalMod amplifier module can host an optional DSP i.e. without the optional DPC interface board. board such as the Powersoft DSP-D and DSP-4 interfaces, In order for the IpalMod to function without a connected as well as any other custom interface. Refer to FIGURE 12 interface board, the CN102 Micro Match connector on the for proper SIMM board dimensions and connectivity.
SOLID ON GREEN SOLID ON active Thermal protection YELLOW TEMP SOLID ON signal clip active No faults, system GREEN READY SOLID ON GREEN ready SOLID ON fully operating GREEN System on SOLID ON protection active 12 | IpalMod | User guide...
In order to guarantee high system performance, the Cabinet proper placement of the pressure sensor on the loudspeaker cabinet and the correct connection of the transducer to the IpalMod are paramount. Pressure sensor WARNING! Inadequate or wrong positioning of the...
This can be done automatically or manually. http://www.powersoft-audio.com/docman/632-power-control-manager/file In order to implement a RS-485 port on a personal computer Powersoft recommend the use of the SPECTRA USB 2.0 to RS-485 converter (browse the SPECTRA web- site www.spectra.ch for further information). A DB9 to RJ45 adapter is needed as well (ref.
14 : 1.1. Automatic discovery 14 : 1.2. Manual discovery 1. Connect the amp module to the computer via the 1. Connect the amp module to the computer via the RS485 connection on the interface board. RS485 connection on the interface board. 2.
The Mute button is provided as well to The input signal can be delayed by user mute audio playback. definable amounts via the delay process- ing block. Parameters can be accessed and set from the main window. 16 | IpalMod | User guide...
15 : 2.Operating modes Current feedback loop The DPC technology can be exploited in two operating Transducer Input modes which differ in signal processing path and applica- Input Output signal gain stage tion scenarios. Radiating Pressure sound field sensor Feedback gain Pressure feedback loop FIGURE 24: Pressure model feedback loop.
Ref SPL: reference sound pressure level (dB): Brownout Brownout is an even faster acting output peak power Ref SPL = 112 + 10 log(no). limiter, and works on a different principle than all other limiters. 18 | IpalMod | User guide...
This protection system quickly reduces the amplifier The hold time indicates how long the gain reduction oc- gain when the rails voltage decrease quickly due to an ex- curs after the output signal falls below the threshold. The cessive power draw from the load. Threshold voltage value attenuation parameter indicates the amount by which the is the value beneath which the rail voltage must drop for the output gain is decreased with respect to no attenuation.
Acou. pwr (W ) – Estimated average acoustic power. Signal – This LED is on when a signal is detected at the input. Avg Rar (Rayls) – Estimated average acoustic impedance. 20 | IpalMod | User guide...
Hardware protections 15 : 8.1. Auxiliary power protections The architecture of Powersoft’s amplifiers encompass several protection mechanisms triggered by harmful signal Auxiliary plugs are protected against short circuit: a and temperature. Protection systems and triggers are inde- poliswitch opens the auxiliary circuits when the current pendently implemented in the power supply section (power drawn exceeds 1 A.
Powersoft dealer (or to Powersoft for repair. In the latter case, before shipping, distributor). You can also contact the Powersoft Technical you are kindly asked to follow step by step the procedure...
Page 33
Specifications AC Mains Supply Output Stage Universal regulated, switch Maximum output power 8500W @ 1Ω Power supply mode, with PFC Maximum unclipped output voltage 180 V peak Nominal power requirement AC 100 V - 240 V, 50/60Hz Maximum output current 110 A peak Operating range...
Page 34
Page intentionally left blank 24 | IpalMod | User guide...
Need help?
Do you have a question about the IpalMod and is the answer not in the manual?
Questions and answers