SiUS091601EA
1.3

FTX18/24UVJU

Control PCB
1)
(PCB1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
12)
13)
14)
S46
S25
S47
JC
Caution
Replace the PCB if you cut a jumper unintentionally.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
Note
The symbols in the parenthesis are the names on the appropriate wiring diagram.
Part 3 Printed Circuit Board Connector Wiring Diagram
S1
Connector for DC fan motor
S21
Connector for centralized control (HA)
S25
Connector for INTELLIGENT EYE sensor PCB (PCB4)
S32
Indoor heat exchanger thermistor (R2T)
S41
Connector for swing motors
S46
Connector for display PCB (PCB3)
S47
Connector for signal receiver PCB (PCB2)
H1, H2, H3, FG Connector for terminal strip
JA
Address setting jumper
Refer to page 207 for details.
JB
Fan speed setting when compressor stops for thermostat OFF
Refer to page 209 for details.
JC
Power failure recovery function (auto-restart)
Refer to page 209 for details.
LED A
LED for service monitor (green)
FU1 (F1U),
Fuse (3.15 A, 250 V)
FU2 (F2U)
V1
Varistor
S41
S1
S21
JA
JB
S32
FU2
LED A
Indoor Unit
H3
FG
H2
H1
FU1
V1
2P227881-6
26