Setting Parameters Of The Reader Module; Configurable Parameters - TECHFASS MREM 82 MTM-MF User Manual

Mifare & nfc reader modules for mtm panels
Table of Contents

Advertisement

5 Setting parameters of the reader module

5.1 Configurable parameters

Parameter
Door lock release time
Door lock control setting
Door lock relay function setting
Permanent door lock release according to
a time schedule
Door lock status indication
Acoustic signal of door lock release
Door ajar time
First input configuration
Second input configuration
Acoustic signalization time - Forced door
Acoustic signalization time – Door ajar
Acoustic signalization time – APB alarm
Signalization time – Card alarm
Antipassback function setting
Automatic summer time adjustment
Release lock with REX button when
tamper alarm active
Online authorization timeout
Standalone authorization after timeout
Saving events in
the module's
archive
Door opened
Door closed
Input 2 On
Input 2 Off
Strike released
Strike closed
Page 12
Possible range
0  255 s
Direct / reverse
Standard / toggle / pulse
Never / Schedule index
YES / NO
YES / NO
0  255 s
Door contact / REX button
REX button / handle contact
/ external tamper / tamper /
disabling function
0  255 s
0  255 s
0  255 s
0  255 s
See chapter 6.10
YES / NO
YES / NO
0  25500 ms
YES / NO
Enabled / Disabled
Enabled / Disabled
Enabled / Disabled
Enabled / Disabled
Enabled / Disabled
Enabled / Disabled
Table 9: Configurable parameters
Default setting
7 s
Direct
Standard
Never
NO
YES
20 s
Door contact
REX button
30 s
0 s
0 s
30 s
Disabled
YES
YES
800 ms
YES
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mrem 82 mtmvr-mf

Table of Contents