Print Results Shift Along The Direction Of X-Axis; Printing Speed Is Too Fast - FLASHFORGE 3D PRINTER Guider IIS Series User Manual

Table of Contents

Advertisement

2. Check the corresponding axis limit switch, plug out the joint of the limit
switch.
9.11 Touch function on the touch screen does not work well.
Fastening screws behind the touch screen are too tightly screwed: Adjust the
tightness of these fastening screws, if not solving, replace a new touch screen.
9.12 Files sliced by Flashprint and transferred by USB stick can not be
identified by printer, or printer prompts: file is not matched.
1.Restart the printer and re-plug out and re-plug in the USB stick.
2.Check to see whether the correct printer type Guider IIS series is selected in
Flashprint.
3.Check to see whether the model size has exceeded limit printing size of
Guider IIS series in Flashprint.
4.USB stick has its own problems, copy the files to printer's internal memory
and start print again, or use a new USB stick.

9.13 Print results shift along the direction of X-Axis.

1. X-Axis timing belt is loosened: Fasten the X-Axis timing belt.
2. X-Axis motor wire has loose contact or broken down: Reconnect the X-Axis
motor wire, if not solving, replace the new motor wire.
3. X-Axis driver board is broken down(step1 and step2 is gradually shifting,
step3 and step4 is whole-part shifting together with abnormal noise): Replace
the new X-Axis driver board.
4.Printing speed is too fast: Lower the printing speed.(Recommended basic
printing speed:40—60mm/s, travel speed:60—80mm/s)
9.14 When doing build plate leveling, touch screen prompts "Please
tighten knobs under the platform" when the knobs have already been
mostly tightened: Re-do the printer's extruder calibration and then do the
build plate leveling again.
Referring operating video: Extruder calibration
https://www.youtube.com/watch?v=VvjT3Y31IAw