Festo 03 Electronic Manual page 93

Valve terminal, field bus connection, field bus protocol: interbus
Table of Contents

Advertisement

VIFB6 - 03/05
Table for calculating the number of inputs/outputs (type 05)
INPUTS
1. Number of 4-input modules
2. Number of 8-input modules
3. The 4 status bits are assigned automatically by the terminal
internally. They must be treated like inputs and must be
added to the intermediate sum
Total sum of inputs to be configured
OUTPUTS
4. ISO sub-base modules for
4 valve locations
*)
8 valve locations
• 12 valve locations
*)
5. Number of electronic output modules
Total sum of outputs to be configured
*) Do not switch on more than 12 valves simultaneously
(the internal fuse will blow).
Fig. 4/3: Calculating the number of inputs/outputs (type 05)
4-8
4. Commissioning
Copy this table for further calculations (type 05).
Σ
______
4
Σ
+
______
8
+
Σ
=
8 O
16 O
Σ
24 O
Σ
+
_______
4
Σ
=
I
I
4 I
I
O
O
O
9809c