Specification; General - BRANNSTROM BilgMon488 Instruction Manual

15 ppm bilge alarm
Table of Contents

Advertisement

7 S
PECIFICATION
7.1 G
ENERAL
Measurement:
Oil range:
Resolution:
Accuracy:
Response time:
Alarms:
Alarm 1 (automatic stopping device) delay:
Alarm 2 (annunciation) delay:
Alarm points 1 and 2:
Alarm hysteresis:
Data storage and retrieval:
Calibration storage:
IMO required data:
Optional data retrieval:
User interface:
LCD display:
Control:
Environment:
Ambient temperature range:
Enclosure ingress protection rating:
Installation:
Sample line inlet operating range:
Sample temperature:
1
0-600 sec on master unit software versions before C9, shown on certificate and in "Info" menu.
0 – 30 ppm
0.1 ppm
According to IMO MEPC.107(49)
< 5 sec
0-10 sec user adjustable
0-60 sec user adjustable
1-15 ppm user adjustable
0.5 ppm (below alarm point)
Stored in sensor housing.
Stored in BilgMon488 main housing (sensor
housing may be replaced with data remaining on
board).
Data retrieval via display.
Via USB port.
2x16 alphanumeric display
4 button keypad
According to IMO MEPC.107(49), (0-55°C)
IP65
Recommended: 1-2 bar (200 – 300 l/h)
Maximum: 3 bar
Maximum: 50 °C
BRANNSTROM SWEDEN AB
www.brannstrom.se
BilgMon488 Instruction Manual vAD 6(38)