8.3 E
LECTRICAL
8.3.1

General installation

Bilgmon488 is manufactured in two base models, 115/230 VAC and 24 V AC/DC. The main difference
between these two models is the base PCB of the MASTER unit.
Illustration 4: Base PCB of 115/230 VAC MASTER unit.
Illustration 5: Base PCB of 24 V AC/DC MASTER unit.
When installing the 115/230 VAC model be sure to put the voltage selection switch (SW1, Illustration
4) in the correct position (marked 115 resp. 230).
Terminals 12-14 (L8, Illustration 4) resp. 13-15 (L8, Illustration 5) are coupled and can be used for
routing of external protective earth connections.
See sections 8.3.3 and 8.3.4 for detailed information of electrical connections.
BilgMon488 Instruction Manual vAD 10(38)
SW1: Voltage selection switch (115/230)
CN2: Terminals 1 – 9
CN3: Terminals 10 - 11
L8: Terminals 12 - 13
CN1: Terminals 16 - 17
CN2: Terminals 1 - 4
CN4: Terminals 5 – 10
CN3: Terminals 11 - 12
L8: Terminals 13 - 15
CN1: Terminals 16 - 17
BRANNSTROM SWEDEN AB
www.brannstrom.se