BRANNSTROM BilgMon488 Instruction Manual page 18

15 ppm bilge alarm
Table of Contents

Advertisement

Example of simulation with explanations:
1) Start in main menu with separator off (separator
status input open).
2) Hold
(do not release until step #7 in this
example).
Automatic stopping device (ASD) is now active
and the alarm2 is not active since the separator is
not running.
3) Press
to simulate that the separator starts
running (toggle to
ASD and alarm2 is now active since the PPM
value is above 15 PPM and the separator is
running.
4) Press
repeatedly until PPM value is below
15.0 ppm (
14.0
ASD and alarm2 is now NOT active since the PPM
value is below 15.0 ppm and the separator is
running.
5) Press
repeatedly until PPM value is above
15.0 PPM (
16.0
ASD and alarm2 is now active since the separator
is running and the PPM value is above 15.0 ppm.
6) Press
to simulate that the separator stops
running (toggle to
ASD is now active and the alarm2 is not active
since the separator is not running.
7) Release
simulation.
3
The VALVE LED and the automatic stopping device output has reversed logic. Hence when VALVE LED is lit the
automatic stopping device is NOT active (overboard valve in discharge position) and vice versa.
SEP_ON
).
or lower value shown).
or higher value shown).
SEP_OFF
).
to return to main menu and end
BRANNSTROM SWEDEN AB
www.brannstrom.se
BilgMon488 Instruction Manual vAD 18(38)
140613 09:50:24
PPM>30.0 SPL
ALARM LED – OFF
VALVE LED – OFF (no discharge)
Simulation
PPM>30.0 SEP_OFF
ALARM LED – OFF
3
VALVE LED – OFF (no discharge)
Simulation
PPM>30.0 SEP_ON
ALARM LED – ON
VALVE LED – OFF (no discharge)
Simulation
PPM=14.0 SEP_ON
ALARM LED – OFF
VALVE LED – ON (discharge)
Simulation
PPM=16.0 SEP_ON
ALARM LED – ON
VALVE LED – OFF (no discharge)
Simulation
PPM=16.0 SEP_OFF
ALARM LED – ON
VALVE LED – OFF (no discharge)
140613 09:50:24
PPM>30.0 SPL
ALARM LED – OFF
VALVE LED – OFF (no discharge)
SPL
SPL
SPL
SPL
SPL

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents