BilgMon488 Instruction Manual vAD 1(38)
INSTRUCTION MANUAL
BilgMon488
15 ppm Bilge Alarm
BRANNSTROM SWEDEN AB
www.brannstrom.se

Advertisement

Table of Contents
loading

Summary of Contents for BRANNSTROM BilgMon488

  • Page 1 BilgMon488 Instruction Manual vAD 1(38) INSTRUCTION MANUAL BilgMon488 15 ppm Bilge Alarm BRANNSTROM SWEDEN AB www.brannstrom.se...
  • Page 2: Table Of Contents

    BilgMon488 Instruction Manual vAD 2(38) ABLE OF ONTENTS Table of Contents ..........................2 Table of validity ..........................4 Introduction ............................. 5 Construction ............................ 5 Operation ............................5 Caution ............................5 Specification ............................ 6 General ............................ 6 Specific 115/230 V AC model ....................7 Specific 24 V AC/DC model ......................
  • Page 3 BilgMon488 Instruction Manual vAD 3(38) 10.7 Acknowledge alarm2 ......................19 10.8 Information menu ......................... 20 10.8.1 Master info ........................20 10.8.2 Sensor info ........................20 10.9 Log ............................21 10.9.1 Log menu ........................21 10.9.2 Step log .......................... 21 10.10 Cleaning &...
  • Page 4: Table Of Validity

    BilgMon488 Instruction Manual vAD 4(38) 17.1 Running the software ......................32 17.2 Installing the VCP driver ......................32 17.3 Download procedure ......................32 Spare parts list ........................... 35 Troubleshooting ........................37 ABLE OF VALIDITY The following table describes the software and hardware versions on which this document was based.
  • Page 5: Introduction

    BilgMon488 Instruction Manual vAD 5(38) NTRODUCTION The BilgMon488 bilge alarm has been designed specifically for use in conjunction with 15 ppm oil- water separator units. BilgMon488 performance meets the requirements of the International Maritime Organisation specifications for 15 ppm bilge alarms contained in resolution MEPC. 107(49).
  • Page 6: Specification

    0.5 ppm (below alarm point) Data storage and retrieval: Calibration storage: Stored in sensor housing. IMO required data: Stored in BilgMon488 main housing (sensor housing may be replaced with data remaining on board). Data retrieval via display. Optional data retrieval: Via USB port.
  • Page 7: Specific 115/230 V Ac Model

    BilgMon488 Instruction Manual vAD 7(38) 7.2 S 115/230 V AC PECIFIC MODEL Input/Output: Current output: 0 – 20 mA or 4 – 20 mA for 0 – 30 ppm Communications: USB serial communication (separate cable and software) Alarm outputs: 2 x relays (0.25A) Clean water solenoid valve output: 1 x relay (0.5A, supply voltage)
  • Page 8: Installation

    BilgMon488 Instruction Manual vAD 8(38) NSTALLATION NOTE: If drain valve is fitted. It should always be closed while separator is running. 8.1 M ECHANICAL Illustration 1: Mechanical installation BRANNSTROM SWEDEN AB www.brannstrom.se...
  • Page 9: Tube Arrangement

    BilgMon488 Instruction Manual vAD 9(38) 8.2 T UBE ARRANGEMENT 8.2.1 Alternative 1 Illustration 2: Tube arrangement alt. 1 8.2.2 Alternative 2 Illustration 3: Tube arrangement alt. 2. BRANNSTROM SWEDEN AB www.brannstrom.se...
  • Page 10: Electrical

    LECTRICAL 8.3.1 General installation Bilgmon488 is manufactured in two base models, 115/230 VAC and 24 V AC/DC. The main difference between these two models is the base PCB of the MASTER unit. SW1: Voltage selection switch (115/230) CN2: Terminals 1 – 9...
  • Page 11: Fresh Water Flushing Valve Installation

    BilgMon488 Instruction Manual vAD 11(38) 8.3.2 Fresh water flushing valve installation This section is valid for systems using a cleaning solenoid according to Illustration 2: Tube arrangement alt. 1 or similar installation. 115/230 VAC model: There are two coils delivered with the BilgMon 488, one to be used with 115 VAC (marked 96 V) and one to be used with 230 VAC (marked 205 V).
  • Page 12: 115/230 Vac

    BilgMon488 Instruction Manual vAD 12(38) 8.3.3 115/230 VAC Illustration 6: 115/230 VAC electrical connections 8.3.4 24V AC/DC Illustration 7: 24V AC/DC electrical connections BRANNSTROM SWEDEN AB www.brannstrom.se...
  • Page 13: Calibration Check

    If the factory issued calibration certificate expires, the SENSOR unit must be replaced. The SENSOR of BilgMon488 is designed to be easily replaced by the crew, see 9.4 Sensor unit replacement. Replacement does not require any adjustments of the MASTER unit setup.
  • Page 14: Operating Instructions

    BilgMon488 Instruction Manual vAD 14(38) 10 O PERATING NSTRUCTIONS 10.1 S TARTUP SEQUENCE When BilgMon488 is powered up the LCD display will show an initialization sequence. Sequence: 1. Internal time reference (Real Time Clock, RTC) is RTC check: checked. In progress! 2.
  • Page 15: 10.2.2 Leds And Indications

    The LED lamps on the front panel indicate the status of the equipment. The straight/dashed lines indicate if the lamps are lit continuously/flashing. (green) Bilgmon488 is in ACTIVE mode (separator is running). BilgMon488 is in POWER mode (menu subsystem is active). ACTIVE POWER (no signal) No alarm2 present.
  • Page 16: Menu System

    Show PPM or STANDBY at inactivity in POWER mode. Standby display See 10.11.8 Standby display. (Select standby notification) Navigation using Navigation using Navigation, see 10.4 - 10.7 1) Transition only possible when BilgMon488 is in POWER mode (see 10.2). Illustration 9: Menu layout BRANNSTROM SWEDEN AB www.brannstrom.se...
  • Page 17: Contrast Adjustment

    PPM value in steps of 1.0. To enter the simulation menu the BilgMon488 needs to be in POWER mode. POWER mode is when the unit is powered but separator is not running (separator status input is open, see 8.3 Electrical).
  • Page 18 BilgMon488 Instruction Manual vAD 18(38) Example of simulation with explanations: 1) Start in main menu with separator off (separator 140613 09:50:24 status input open). PPM>30.0 SPL ALARM LED – OFF VALVE LED – OFF (no discharge) 2) Hold (do not release until step #7 in this Simulation example).
  • Page 19: Force Automatic Stopping Device Activation

    10.7 A CKNOWLEDGE ALARM If separator is running (separator status input is closed, BilgMon488 in ACTIVE mode) and the PPM value goes above 15.0 ppm the unit will generate an alarm2 (alarm2 output terminal and LED). The alarm2 can be acknowledged by pressing .
  • Page 20: Information Menu

    BilgMon488 Instruction Manual vAD 20(38) 10.8 I NFORMATION MENU The information submenus will display information about the MASTER and the SENSOR unit of BilgMon488 according to examples below: 10.8.1 Master info Cycle 0: Master info Menu name. Cycle 1: Master ID: Serial number.
  • Page 21: Log

    BilgMon488 Instruction Manual vAD 21(38) 10.9 L The log menu enables the user to search and step the IMO-regulated log of the BilgMon488 as well as download parts of or the entire log to file using the “BilgMon488 log download kit” (purchased separately).
  • Page 22: Cleaning & Test

    TEST 10.10.1 Clean cell (zero calibration) The clean cell menu provides the facility to zero calibrate the BilgMon488. It is also a useful tool for checking on dirt, layering and scratches on the sample tube inside the SENSOR unit. Values shown range from 0% (clean, same values as factory calibration) to 100% (dirty) where 50% or below is required to perform zero calibration.
  • Page 23: Test Outputs

    BilgMon488 Instruction Manual vAD 23(38) 10.10.3 Test outputs The test outputs menu is used for testing the function of the separator status input as well as the alarm2, automatic stopping device and fresh water flushing valve outputs (see 8.3 Electrical).
  • Page 24: Autoflush Feature (Automatic Freshwater Cleaning)

    10.11.4 Set clock The BilgMon488 has an internal timekeeping mechanism with a battery backup. This mechanism is refered to as RTC (Real Time Clock). The RTC is set at production to UTC time (Coordinated Universal Time).
  • Page 25: Curro Mode (Current Output Mode)

    10.11.5 Curro mode (Current output mode) The current output of BilgMon488 can be altered between two modes, 0-20 mA and 4-20 mA. These intervals correspond to 0-30 ppm oil content as displayed in the main menu.
  • Page 26: Ppm Display. (Select Number Of Decimals In Ppm Display)

    BilgMon488 Instruction Manual vAD 26(38) 10.11.7 PPM display. (Select number of decimals in ppm display) Select between one decimal (default) and no decimal when displaying the PPM value. Press to display the cursor. display: DECIMAL Press to toggle between “ONE DECIMAL” and “NO DECIMAL”.
  • Page 27: Automatic Stopping Device Test

    To make step 1 of the response test affect alarms and valves the apparatus needs to be active. Bilgmon488 is activated (flashing green led) when in main menu and the separator input signal is active. Activation can be done by shorting the “separator status” input (see 8.3 Electrical). This method is not recommended since there is an obvious risk of forgetting the strap and that it requires opening the MASTER unit.
  • Page 28: Log Entries

    BilgMon488 Instruction Manual vAD 28(38) 14 L OG ENTRIES Type Example Explanation POWER ON Power was turned on at given date Log: POWER ON and time (yymmdd hh:mm:ss). 060102 11:36:32 POWER OFF Power was turned off. Log: POWER OFF 060102 14:06:10...
  • Page 29: Maintenance

    15 M AINTENANCE The BilgMon488 can be set to autoflush (see 10.11.3 Autoflush feature (automatic freshwater cleaning)). This means that the sensor tube is flushed with clean water at durations and intervals as set in the settings menu. Autoflush is only active when in main menu and BilgeMon488 is not active.
  • Page 30: Real Time Clock (Rtc)

    16.1 L OCAL TIME In the settings of each Bilgmon488 there is a possibility to adjust the displayed time. This affects how time and date are displayed on the display (main menu, log items etc.). This setting is stored and used as an offset to the internal time (RTC-time).
  • Page 31: Set Utc Time

    BilgMon488 Instruction Manual vAD 31(38) ERROR: ERROR: RTC malfunction! Press ENTER! alternating with When pressing the user enters the RTC recovery menu (see Illustration 11: RTC recovery menu layout). Set internal time reference. Set UTC time: See 16.3.1 Set UTC time Step, search and download the log.
  • Page 32: Log Data Download Via Usb

    Apart from inspecting the log via the LCD (see 10.9 Log) there is a possibility to download the log via a USB-connection to a personal computer running Windows operating system. NOTE: This procedure requires the “Bilgmon488 log data download kit” consisting of a CD with software and a USB cable.
  • Page 33 100 from current (000A:4567) Number of logs? 12343 entries ”Long” Log: PPM > 15 Sending log! 140601 23:12:33 ”Wait” Send log? Sending log! Sent 12343! Illustration 14: Send log data from Bilgmon488 Illustration 15: Log data download completed BRANNSTROM SWEDEN AB www.brannstrom.se...
  • Page 34 (VCP3) and listening). 6. On your BilgMon488 navigate to the log-menu and step in to the log. When exiting the log you will be asked if you want to send the log. Answer yes and choose the amount of data to download (see Illustration 14: Send log data from Bilgmon488).
  • Page 35: Spare Parts List

    BilgMon488 Instruction Manual vAD 35(38) 18 S PARE PARTS LIST Order nr. by model Description 115VAC 230VAC 24V AC/DC Complete unit 1, 2, 3 BM488-115 BM488-230 BM488-24 (Master, Sensor and Freshwater valve) Sensor unit BM488MC Master unit BM488MU-115 BM488MU-230 BM488MU-24...
  • Page 36 BilgMon488 Instruction Manual vAD 36(38) Illustration 16: General assembly/Spare parts BRANNSTROM SWEDEN AB www.brannstrom.se...
  • Page 37: Troubleshooting

    BilgMon488 Instruction Manual vAD 37(38) 19 T ROUBLESHOOTING Symptom Possible reason(s) Servicing BilgMon488 is switched on but Power supply is erroneous. Check connections internally, LCD remains blank. externally and power supply voltages. LCD monitor is broken. Order replacement part. Automatic fuses blown.
  • Page 38: Bilgmon488 Instruction Manual Vad

    BilgMon488 Instruction Manual vAD 38(38) BRANNSTROM SWEDEN AB www.brannstrom.se...